130525 QC3 Filter and Dryer Unit
DESCRIPTION
This is a point of use unit designed
to remove water, dirt, oil and
humidity.
SPECIFICATIONS:
Air Inlet:
1/2 NPT (male)
Air Outlet:
1/4 NPSM (male)
Pressure Drop: 2 psi (at 30 psi
flowing 16 cfm)
Max. Pressure: 150 PSI
Max. Temp.:
150° F
Filter Size:
0.1 micron
Material Safety Data Sheet MSDS-55
available upon request at
www.autorefinishdevilbiss.com.
Risk of personal injury.
Risk of property damage.
RELEASE ALL AIR PRESSURE
BEFORE SERVICING.
This product is specifically designed
for compressed air service. Use with
any other fluid (liquid or gas) is a
misapplication. For example, use
with or injection of certain hazardous
gases in the system (such as oxygen
or liquid petroleum gas) could be
harmful to the unit or result in a
combustible condition that may cause
fire or explosion. Manufacturer's
warranties are void in the event of
misapplication and manufacturer
assumes no responsibility for any
resulting loss.
INLET AIR
FIGURE 1
DRAIN
INSTALLATION
1. Assemble per Figure1 and fasten
to wall.
2. Store wrench in top as shown.
For optimum performance, install at
least 20 feet from the compressor.
OPERATION
1. Turn the regulator's handle
clockwise to increase pressure.
2. To decrease pressure, turn the
handle counterclockwise.
3. Relieve downstream pressure by
triggering spray gun or tool.
UNION
MAINTENANCE
DAILY:
• IMPORTANT – Drain filter.
• Check indicator:
Blue = OK
Pink/White = Replace Cartridge
See Filter Cartridge Replacement,
page 2.
SERVICE PARTS
See Parts List, page 3.
Service Bulletin
SB-6-190-E
Patents Pending
Replaces SB-6-190-D
AIR OUT