SILENCER HOUSING MOUNTING INSTRUCTIONS

The 'SCL K-TS' series was designed to provide maximum
flexibility in the positioning of the silencer housings to meet
various installation configurations.
The blower is supplied with the silencers configured as in Fig. 1
If this configuration needs to be modified, proceed as
follows:
4.1
SILENCER HOUSING MOUNTING FOR
K04-TS
1.
Identify the desired configuration (Fig.2, Fig.3, Fig.4).
2.
Disassembly of the silencer housing:
2.1 Remove the #904 screws.
2.2 Take away the #700 silencer from the unit along with the
#424 gasket.
3.
Disassembly of the #730 blind flange:
3.1 Remove the #909 screws, taking away the #730 flange
along with the #427 gasket.
3.2 Reassemble in reverse order-do not forget the #427
gaskets.
162
427
909
730
Fig.1
K03-TS
/
424
904
700
Fig.2 with 90° manifold
90° manifold
Fig.2
GB - 19/48
4.1.1
USING
THE
90°
(accessory) FOR K03-TS / K04-TS
The 90° manifold can only be installed on the #162 cover ports
and as shown in the Figures below, there are multiple
configurations.
The 90° manifold kit type CK comes supplied with
1 x manifold
1 x #427 gasket and
4 x M6x25 UNI 5931 screws.
To mount the 90° manifold, proceed as follows:
1.
Disassemble the silencer housing (see paragraph 4.1 -
point 2).
2.
Disassemble the blind flange (see paragraph 4.1 - point 3)
3.
Place the #427 gasket between the #162 cover and the 90°
manifold and seal with the M6x25 UNI 5931 screws.
4.
Assemble the silencer housing in reverse order-do not
forget the #424 and #427 gaskets.
Fig.3 with two 90° manifolds
90° manifolds
Fig.3
MANIFOLD
KIT
TYPE
Fig.4 with 90° manifold
90° manifold
Fig.4
CK