Packing List

Name
Keypad
User manual
Screw driver
Rubber plug
Self tapping screws
Star screws
Please ensure that all the above contents are correct. If any are missing please notify the supplier
of the unit.

Installation

• Remove the back cover from the keypad using the supplied special screw driver
• Drill 2 holes on the wall for the Self tapping screws and I hole for the cable
• Put the supplied rubber bungs to into the two holes
• Fix the back cover firmly on the wall with 2 Self tapping screws
• Thread the cable through the cable hole
• Attach the keypad to the back cover

Wiring

Colour
Function
Pink
BELL_A
Pale blue
BELL_B
Green
White
Yellow
OPEN
Red
12V+
Black
Blue
Purple
COM
Orange
Quantity
1
1
1
2
2
1
Description
Doorbell button one end
Doorbell button to the other end
D0
WG output D0
D1
WG output D1
Exit button one end(the other end connected GND)
12V + DC Regulated Power Input
GND
12V - DC Regulated Power Input
NO
Relay normally-on end(Connect positive electric lock "-")
Relay Public end, connect GND
NC
Relay Closed end(connect negative electric lock "-")
Remarks
Φ20mm×60mm,Special for keypad
Φ6mm×30 mm , used for fixing
Φ4mm×28 mm , used for fixing
Φ3mm×6mm, used for fixing