PARTS AND SPECIFICATIONS
A. Construction and characteristics
•
Transportable terrace/garden heater with tank housing.
•
Casing in steel with powder-coating or in stainless steel.
•
Gas hose connections with metal clamp (screw caps for Germany). Heat emission from reflector.
B. Specifications
•
Use propane, butane or their mixtures gas only.
•
Max. wattage: 14000 watts
•
Min. wattage: 5000 watts
•
Consumption:
APPLIANCE CATEGORY:
TYPES OF GAS:
GAS PRESSURE
OUTLET PRESSURE
OF REGULATOR:
Using the proper regulator according to outlet pressure of regulator as showed in the table above.
C. Table of injector
APPLIANCE CATEGORY:
TYPES OF GAS:
GAS PRESSURE
TOTAL HEAT
INPUT
(Hs): (Qn)
INJECTOR SIZE
1.90 mm for main burner
0.18 mm for pilot burner
The marking, for example, 1.90 on the injector, indicates that the size of injector is 1.90 mm
•
The hose and regulator assembly must conform to local standard codes.
•
Regulator outlet pressure should meet the corresponding appliance category in B. Specification.
•
The appliance requires approved hose in 1.4m length.
A regulator (compliees with EN16129:2013 and the national regulation) of the correct pressure corresponding to the appliance category.
Use 30mbar regulator for butane/propane under the category I3B/P(30). Use 30mbar regulator for butane under the category I3+(28-30/37).
Use 37mbar regulator for propane under the category I3+(28-30/37).
Use 50mbar regulator for butane/propane under the category I3B/P(50).
It's recommended to use flexible hose that approved by EN16436: 2014.
I3+(28-30/37)
Butane
Propane
28-30 mbar
37 mbar
30 mbar
30 mbar
I3+(28-30/37)
Butane
Propane
28-30 mbar
37 mbar
I3B/P(30)
Butane, propane or
their mixtures
30 mbar
30 mbar
I3B/P(30)
Butane, propane or
their mixtures
30 mbar
14 kW (1000 g/h)
1.70 mm for main burner
0.18 mm for pilot burner
I3B/P(50)
Butane, propane or
their mixtures
50 mbar
50 mbar
I3B/P(50)
Butane, propane or
their mixtures
50 mbar
EN