- Identification plate situated on the 2500W power supply unit (P.S.U.) :
Standard version :
ALIMENTATION POUR LAMPE A DECHARGE
1
DISCHARGE LAMP POWER SUPPLY UNIT
Lire le manuel avant utilisation - Utilisation et maintenance par professionnel
uniquement / Read manual before use - Service only by qualified personnel.
MOD.
2
U
in
208/245V 50/60Hz AC
0,90...1,00
COS
0...40°C
70°C
t°a
t°c
.com
3
North-American version :
ALIMENTATION POUR LAMPE A DECHARGE
1
DISCHARGE LAMP POWER SUPPLY UNIT
Lire le manuel avant utilisation - Utilisation et maintenance par professionnel
uniquement / Read manual before use - Service only by qualified personnel.
MOD.
2
U
208V 2PH 60Hz
in
0,90...1,00
COS
0...40°C
70°C
t°a
t°c
.com
3
Description :
1 Mains checklight.
2 2 pole, 6A circuit breaker.
3 2 pole, 25A circuit breaker.
4 1 pole, 1A circuit breaker.
5 Ventilation opening
6 EF HARTING 16 x 16A - 2 latch connector.
7 Mains cable 3 x 4mm
(Standard version).
Mains cable 3 x 12 AWG (1,50m) without plug
(North-American version).
8 Control module (depending on configuration).
9 Rating plate.
10 Power supply selector :
208V. 60Hz, 230V. 50Hz & 245V. 50Hz.
Position locked by a screw.
Technical characteristics :
Nominal absorbed power : .................................................................... 3100 W
Voltage use (*) Standard version : ...................................... 230/245 V 50 Hz
Voltage use (**) North-American standard : .............................. 208 V 60Hz
Minimum voltage of the power supply : .................................................198 V
(Below this charge = possible ignition failure).
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
USER'S INSTRUCTIONS
5
7
8
VERS.
6
max. 12A
I
in
3100W
Pa
20
IP
Made in the EU - France -
4
5
7
8
VERS.
6
max. 16A
I
in
3100W
Pa
20
IP
Made in the EU - France -
4
5
3 4
2
1
10
9
6
7
(DON'T OBSTRUCT THE AIR GAPS).
2
(3m) + P17 32A+E plug
1 Power supply description.
2 Power supply reference & technical characteristics :
- MOD. = Unit model.
- VERS. = The unit version.
- Uin = Nominal voltage input.
- Iin = Nominal intensity.
- COS = Phase shift between the voltage & current.
- Pa = Power absorbed.
- t°a = Surrounding temperature.
- t°c = Maximum external temperature of the unit.
- IP 20 = Indication of protection :
IP20 = indoor use ONLY.
3 Logo, manufacturer's name and origin of the product.
4 Serial number.
5 European conformity.
6 Net weight.
7 WEEE directive label.
8 User's instructions.
Units :
- Dimensions
= metre (m) millimetre (mm).
- Weight
= kilogram (kg).
- Intensity
= Ampere (A) milliampere (mA).
- Voltage
= Volt (V).
- Frequency
= Hertz (Hz).
- Power
= Watt (W).
- Temperature = Degree Celsius (°C).
Manual control module :
8
A - Lamp ON, checklight.
B - "ON/OFF" switch.
ON
When the switch is ON and the
B
0
I
OFF
checklight is OFF, the lighting of
A
C
the lamp has failed.
Repeat the operation.
C - External control by a straight closing
contact (1A - 250V).
CAD 900 control module :
A - EM XLR5 input DATA.
0/10V - DMX 512 - AVAB
B - EF XLR5 output DATA.
SELECT
EXIT
+
C
A
C - EM XLR4 0/+10V input.
RESET
D
B
D - EF XLR7 output DATA luminaire.
DATA
0/10V
CONTROL
SHUTTER
CAD 2000 control module :
A - EM XLR5 input DATA.
B - EF XLR5 output DATA.
B
C - EF XLR5 output DATA luminaire.
A
C
(Refer also to section B - 6).
2500W
MAGNETIC P.S.U.
Section A - 3