Operating instructions for hand-held pendant stations HBLS
Technical data, general
Parameters
Housing material
Colour
Operating temperature
Storage temperature
Humidity, max.
Condensation not permissible
Degree of protection
according to EN 60529 / IEC 529
NEMA
Weight
Resistance to
vibration
Vibrations (3 axes)
Shock (3 axes)
EMC protection requirements
in accordance with CE
Power supply
Operating voltage U
DC
B
Operating current, max.
Output, max.
Communications interface
Type RS422A or
RS232 (lead length max. 30 m)
Technical data of
components
EMERGENCY STOP
Norm
Switching elements
Utilization category
according to IEC 60947-5-1
Enabling switches ZSG
Switching element
Utilization category
according to IEC 60947-5-1
Other components
See EUCHNER catalogue for hand-held pendant stations or
www.euchner.de
Technical data, handwheel
See relevant operating instructions for HKD
handwheel.
Accessories
See EUCHNER catalogue for hand-held pendant
stations or www.euchner.de
EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D 70771 Leinfelden-Echterdingen Tel. +49 711 7597-0 Fax +49 711 753316 info@euchner.de www.euchner.de
Value
Polyamide
Blue-grey RAL 7031
0 °C to +55 °C
-20 °C to +55 °C
80 %
IP 65
250-12
1.7 to 3.2 kg
DIN/IEC 68-2-6
DIN/IEC 68-2-27
EN 61000-6-2
EN 61000-6-4
24 V ± 20%
200 mA
4.8 VA
See manual
Value
EN ISO 13850
Max. 2 NC contacts
DC-13
U
=24 V / I
= 3 A
e
e
Value
Max. 2 NO contacts
DC-13
U
=24 V / I
= 3 A
e
e