Pinch point hazard. Crimp ram operates with high force and can cause severe personal
injury. Keep all body parts away from moving parts of the tool during operation
Hydraulic fluid under pressure. Do NOT use any part of your body to locate a hydraulic
leak. Escaping fluid under pressure can cause severe injury or death. If injury results from
escaping hydraulic fluid, seek immediate medical attention to avoid serious bodily injury
Do NOT over-reach while operating this tool. Loss of balance can cause serious personal
injury or death. Move closer to work area and securely support yourself and your work.
ALWAYS keep proper footing and balance
Use all appropriate personal safety equipment when handling, operating, and
servicing this tool such as: safety shoes, hard hat, eye and ear protection, work
gloves, and sleeves.
To help ensure safe operation of this tool, keep all safety labels clean and legible.
Replace labels when necessary with new labels. See the PARTS SECTION of this
manual for information on reordering. Safety is everyone's responsibility.
2. INTRODUCTION
The P703F is a lightweight foot pump made of aluminium alloy. It has two speed operations: rapid and
slow and has an automatic switch from the first stage to the second stage. Also, the pump is provided
with boost pressure valve which forgives reaching the maximum tolerance level in operating conditions.
The operating pressure is set in SBI's factory at a level of 700 bar.
2.1 Characteristics of the P703F foot pump
Maximum pressure: 700 bar.
Two speed operations: the first stage is rapid (approach), the second one is slow (pressure).
There is an automatic switch from the first stage to the second stage.
Rapid connection: The pump is supplied with a high-pressure hose with hydraulic connector and
can be connected to crimping or cutting hydraulic heads.
Security: The pump is equipped with a boost pressure valve.
2.2 P703F foot pump description
1
6
All manuals and user guides at all-guides.com
2
3
7
4
7
5