Page 12
Physical:
Height
Width
Depth (excludes bezel)
Weight
Environmental:
Temperature
Operating
Storage
AXIS S1032
42.8 mm (1.68 inch)
With rack latches 482.4 mm
(18.99 inch)
Without rack latches 434.0
mm (17.09 inch)
607.0 mm (23.9 inch)
13.6 kg (30.0 lb)
AXIS S1032
Continuous operation: 10 °C
to 35 °C at 10% to 80%
relative humidity (RH), with
26 °C max dew point. De-rate
maximum allowable dry bulb
temperature at 1 °C/300 m
above 900 m (1°F per 550 ft).
Note:
For information on
supported expanded
operating temperature
range and configura-
tions, see sup-
port.dell.com/
manuals.
–40 °C to 65 °C (–40 °F to 149
°F) with a maximum
temperature gradation of 20
°C per hour
AXIS S1032/AXIS S1048 Installation Guide
AXIS S1048
86.8 mm (3.41 inch)
With rack latches 482.4 mm
(18.99 inch)
Without rack latches 434.0
mm (17.09 inch)
646 mm (25.4 inch)
18.9 kg (41.7 lb)
AXIS S1048
Continuous operation: 10 °C
to 35 °C at 10% to 80%
relative humidity (RH), with
29 °C max dew point. De-rate
maximum allowable dry bulb
temperature at 1 °C/300 m
above 950 m (1°F per 550 ft).
Note:
For information on
supported expanded
operating temperature
range and configura-
tions, see sup-
port.dell.com/
manuals.
–40 °C to 65 °C (–40 °F to 149
°F) with a maximum
temperature gradation of 20
°C per hour