Télécharger Imprimer la page

Publicité

Liens rapides

DS-PWA32-H
Wireless Security Control Panel
UD13151B-A
E N G L I S H
Diagram References
Appearance
1
Note: The function of GPRS or 3/4G(implemented with build-in SIM card slot) depends on the model of the device.
Power On
Arm
Armed
2
4
1
2
AC Power
/Disarm
Disarmed
Power Off
System Fault
2
2
Fault
Alarm Occurred
2
5
Alarm
No Fault
Device Tampered
No Alarm
Panel is added to
10
2
3
Link
Hik-connect account
11
Panel is not added to
12
Hik-connect account
Note: Remove the rear cover, and some of the components and interfaces are on the rear panel.
Installation
2
1. Loosen the screw on the rear cover. Slide down the rear cover and remove it from the
control panel.
2. Insert a SIM card into the SIM card slot.
3. Connect the battery to the control panel.
4. Connect the power adapter to the control panel and a power outlet. The power indicator
turns green about 30s later, which means that the device is powered on.
Note: The condition of no SIM card, no battery, AC power off, or network disconnected, will cause Control Panel Fault.
5. Connect the Ethernet cable to an internet outlet. While the device is added to a Hik-Connect
account, the link indicator turns green.
6. Secure the rear cover in the installation position with the supplied screws. Attach the
control panel on the rear cover, and tighten the rear cover screw to complete the installation.
Side Opening
If you need to route the cable though the botton of the panel, remove the sheet of the side
opening.
TAMPER Screw
It is compulsory to secure the TAMPER screw.
Set Up
3
Set up via APP
1. Log into the App Store or Google Play and input Hik-Connect to search and install the
mobile client.
2. Log into the APP with Hi-Connect account.
3. Tap Add Device. Scan the device QR code on the rear panel(on the lable).
4. Tap Connect to a Network. Select Wireless Connection (AP) as the connection mode.
5. Push the AP/STA mode switch to the AP position, tab Confirm.
6. Tap Connect to Wi-Fi on the promt-up window. Select and connect to a stable Wi-Fi , and
click Next.
7. Create a password to activate the device.
8. Push the AP/STA mode switch to the STA position.
Note: You need to enter the Verification Code (on the device lable which is pasted on the rear panel) before
activation if you add the device by entering the device serial No.(SN).
Set up via Web Client
Log Into the Web Client
Default IP Address when using mobile broswer in the AP mode:192.168.8.1. The device must be in the AP mode.
Default IP Address when connectiing the network cable with computer directly :192.0.0.64
Input the device IP address in the address bar of the web browser. Create a password to
activate the device and log into the web client.
Add a Camera for the Zone
1. Click System-Network Camera, and you can add two cameras for the control panel.
2. Click Wireless Device-Zone, select a zone, click the Settings icon, and select a camera to link
with the zone.
You can also link a camera with the zone via APP, refer to the Wireless Security Control Panel
User Manual for details.
Configure Video-Push
You can view the alarm video via APP and email.
For detailed settings, refer to Security
Control Panel User Manual.
Set up via 4200 Client
1. Download and install the iVMS-4200 client.
Note: Get the client software from the official website:www.hikvision.com.
2. Enter Device Management page, select the device in the Online Device List, click Edit
Network Settings, change the port as 80, and click Add to Client.
Note: You should activate the device for the first usage.
For multi-language switch , refer to Security Control Panel User Manual (scan the QR code) for details.
Function Button Operation
4
Note: Add card or keyfob via the web client before adding peripheral device for clearing tampering alarm.
Add Peripheral Device
While the control panel is not in the configuration mode, press the function button on the
side of the control panel once and trigger a peripheral device.
Note: Keyfobs cannot be added by function button operation.
Check RF Signal
While the control panel is not in the configuration mode, double press the function button,
and you can check the RF signal strength on the peripheral device .
Specification
Alarm Input
32
Alarm Output
32
Wireless Device
Siren
2
Connection
Keyfob
8
Partition
1
Interaction
Audio Output
1, 1.5W
RF Frequency
433/868MHz
RF
RF Modulation
2GFSK
RF Distance
800m(Open Area)
Wired Network
Ethernet
10M/100M Self-adaptive
Supports report push-notification to ARC & Cloud, text
Cellular Network
GPRS, 3/4G
notification via SMS, and audio notification via phone call
Standard
802.11b/g/n
Wi-Fi
Encryption
Supported
Channel
2.4G
Application &
Application
iVMS-4200, and mobile APP
Protocol
Protocol
SIA - Contact ID
User
User
13 (1 Installer, 1 Administrator, and 11 General User)
Power
5 VDC,10W
Consumption (without HDD)
<5.6W
Operation Temperature
–10℃ to 55℃
Others
Operation Humidity
10% to 90%
Shell Material
PC+ABS
Dimension(WxHxD)
155 x155x35mm
DS-PD2-P10P-W
Wireless 10m Pet Immune PIR Detector
EN50131-2-2:2008
EN50131-1:2006+A1:2009
Environmental Class (EC) II
Security Grade (SG) 2
E N G L I S H
Diagram References
1
Wireless device control
2
Registration
Please register the detector within 90 seconds after it being powered on.
Add Locally
1. Make the security control panel enter the registration mode.
2.Add the detector: Hold the registration key until the three LEDs flash
alternately.The green LED will flash 8 times if the registration is finished.
3. Communication Test: Release the TAMPER spring to trigger the alarm.
Note:
The distance between the security control panel and the detector
should be less than 50 cm.
Initialize the Detector
1.Remove the battery to power the detector off.
2. 5s later,hold the registration key and reinstall the battery to power the
detector on at the same time to make the three LEDs start flashing alternately.
Release the registration key while the three LEDs flash once together.
3
Diagnostics(Check Signal Strength Before Mounting)
Make sure the LED keeps green at the installation position when the detector is in
the signal strength mode before mounting.
4
Brackets Wiring
Specification
Detection Range
10m
Detection Angle
85°
Lens characteristics
Detection Zones
56 zones and 6 planes
Detection Speed
0.3–3.0 m/s
Mounting Height
1.8-2.4m
Animal Immunity
24kg
Blue Wave Technology
Supported
Digital Temperature
Supported
Key features
Compensation
Front, rear, and bracket tamper
Tamper Protection
signal input
Signal Strength Indicators (SSI) Supported
Frequency
433/868MHz
Wireless
Modulation
2GFSK
Range in open space
800m
3V lithium battery included
1x CR123A
Electrical specifications
General battery life (years)
2
Operating | storage
-10°C to +40°C (Certified)
Other details
Weight
125g
Dimensions(H x W x D)
117 x 69 x 50mm
Ceiling Mounted Bracket
Supported
Accessories
Wall Mounted Bracket
Supported
Battery Information
The batteries supplied have been chosen to provide long service life
whilst, for safety reasons, having limited output current.The battery is
protected on purchase by a piece of plastic that must be removed for
operation. When disposing of the product, the battery must be removed
and disposed of separately in accordance with the local regulations.
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable harmonized
European standards listed under the RE Directive 2014/53/EU,
the RoHS Directive 2011/65/EU.
For electrical products sold within the European
Community. At the end of the electrical products
life, it should not be disposed of with household
waste. Please recycle where facilities exist. Check
with your local Authority or retailer for recycling
advice in your country.
1
1
2
2
2
2
3
2
4
2
5
2
SIM Card Slot
6
7
2
Tamper Spring
2
8
Reset Button
9
2
AP&STA Switch
2
Battery Connector
2
Network Interface
2
Power Interface
2
2 4
Cable Pipe
Cable Pipe
3
1
HIGH
LOW
3
5s
+
-
4
Hangzhou Hikvision Digital Technology CO.,Ltd.
2
2 1
2
6
2
7
2
10
2
8
11
2
9
2
12
2
2 5
Cable Pipe
Cable Pipe
Recommended Power Adaper
Manufactory: Shenzhen HONOR Electronic Co., Ltd
Model: ADS-12B-06 05010E
Input rating: 100-240V~50/60Hz Max. 0.3A
Output rating: 5V 2.0A
2
2
2
7
LED ON
LED OFF
HIGH
+
+
+
+
LOW
+
+
+
+
REGISTRATION
+
-
<24kg
>24kg
A
C
B
No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
2 2
2 6
CR123A
LITHIUM
-
TAMPER
+
-
+
>5s
REAR TAMPER
BREAK-OUT
E
WALLBRACKET
D
2 3
Tear off
CAUTION
RISK OF EXPLOSION IF BATTERY IS
REPLACED BY AN INCORRECT TYPE
DISPOSE OF USED BATTERIES
ACCORDING TO THE INSTRUCTIONS
This product and - if applicable - the supplied accessories too
are marked with "CE" and comply therefore with the
applicable harmonized European standards listed under the RE
Directive 2014/53/EU, the EMC Directive 2014/30/EU, the LVD
Directive 2014/35/EU, the RoHS Directive 2011/65/EU
2012/19/EU (WEEE directive): Products marked with this
symbol cannot be disposed of as unsorted municipal waste in
the European Union. For proper recycling, return this product
to your local supplier upon the purchase of equivalent new
equipment, or dispose of it at designated collection points. For
more information see: www.recyclethis.info
2006/66/EC (battery directive): This product contains a
battery that cannot be disposed of as unsorted municipal
waste in the European Union. See the product documentation
for specific battery information. The battery is marked with
this symbol, which may include lettering to indicate cadmium
(Cd), lead (Pb), or mercury (Hg). For proper recycling, return
the battery to your supplier or to a designated collection
point. For more information see:www.recyclethis.info
4
=
BRACKET TAMPER
SEE SECTION4
=
REGISTRATION
-
HORIZONTAL COVERAGE
10m
85
°
56 ZONES
9m
6 PLANES
8m
7m
6m
5m
4m
3m
<24kg
2m
1m
3m
4m
6m
7m
10m
1m
2m
5m
8m
9m
VERTICAL COVERAGE
2.4m
10m
1m
2m
3m
4m
5m
6m
7m
8m
9m
CEILINGBRACKET
B
C
A

Publicité

loading

Sommaire des Matières pour HIKVISION DS-PWA32-H

  • Page 1 1. Download and install the iVMS-4200 client. Input rating: 100-240V~50/60Hz Max. 0.3A Note: Get the client software from the official website:www.hikvision.com. Output rating: 5V 2.0A 2. Enter Device Management page, select the device in the Online Device List, click Edit Network Settings, change the port as 80, and click Add to Client.
  • Page 2 Any and all information, including, among others, wordings, pictures, graphs are the properties of Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries (hereinafter referred to be “Hikvision”). This user manual (hereinafter referred to be “the Manual”) cannot be reproduced, changed, translated, or distributed, partially or wholly, by any means, without the prior written permission of Hikvision.
  • Page 3 2. Accédez à la page « Gestion des dispositifs », sélectionnez le dispositif dans la liste Nota: Obtenga el software de cliente en la página web oficial: www.hikvision.com. dall'elenco di dispositivi online, fare clic su Modifica impostazioni di rete, inserire веб-сайте...
  • Page 4 DS-PD1-MC-WWS Wireless Magnetic Contact Français Português Italiano Español Русский Références du schéma Referências do diagrama Riferimenti agli schemi Diagrama de referencia Пояснения к схемам Le capteur peut détecter l’ouverture de la porte ou de la fenêtre. O sensor pode detectar a abertura de portas e janelas. Quando uma Il sensore è...
  • Page 5 Uwaga: oprogramowanie klienckie można pobrać z oficjalnej witryny internetowej Peripheriegeräte hinzuzufügen. 1. Sprawdź siłę sygnału Hinweis: Die Client-Software erhalten Sie über die offizielle Website: www.hikvision.com. www.hikvision.com. 2. Gehen Sie auf die Seite „Geräteverwaltung“, wählen Sie das Gerät in der 2. Wyświetl stronę Zarządzanie urządzeniami, wybierz urządzenie na liście Meldermontage Przełącz do trybu sprawdzania sygnału przy użyciu centrali...

Ce manuel est également adapté pour: