PRODUCT PRESENTATION
NF S61-937 - PV n° SD190043
Surface mount
High corrosion resistance
Security rope
No mechanical wear
Ease of installation
Recommended for interior use
Fail safe (Door unlocked when power off)
Holding force : 300 kg
No residual magnetism
Visual signaling (Blue = Locked ; Green = Open)
Built-in varistor : built-in electronic protection
to eliminate back EMF
Dimensions (L x W x D) : 254 x 45 x 27 mm
Armature plate dimensions (L x W x P) : 185 x 38 x 11mm
Power supply : 12/24/48V dc
Consumption : 480 mA with 12V dc
240 mA with 24V dc
120 mA with 48V dc
DEEE & RoHS
Certifi cation CE
PACKAGE CONTENT
Magnetic lock
Armature plate
1
1
Steel Rubber Rubber washer M8x35 Screw
2
1
NORME
Side load 100kg compliant.
Automatic voltage selection
Correspondence :
+ 12/24/48V dc
- 0V
Important information :
Respect the polarity.
Do not change the position of the jumper
except if using the Fire controller. Refer to the
Fire installation manual.
CDVI FRANCE + EXPORT
CDVI UK
31, av. du Général Leclerc
[UNITED KINGDOM - IRE-
93500 PANTIN - France
LAND]
Phone +33 (0)1 48 91 01 02
Phone +44 (0)1628 531300
www.cdvi.com
www.cdvi.co.uk
CDVI SWEDEN
CDVI AMERICAS
[SWEDEN - DENMARK -
[CANADA - USA]
NORWAY FINLAND]
Phone +1 (450) 682 7945
Phone +46 (0)31 760 19 30
www.cdvi.ca
www.cdvi.se
Manufacturing Access Control since 1985
YEAR
IP42
Fixing plate
Security Rope
5x16 Roll pin
1
2
M8x25 Screw
1
1
CDVI BENELUX
[BELGIUM - NETHERLAND -
LUXEMBOURG]
Phone +32 (0) 56 73 93 00
www.cdvibenelux.com
CDVI SUISSE
Phone +41 (0)21 882 18 41
www.cdvi.ch
V3SR1248 - FREE VOLTAGE
300 kg Mount Electromagnetic lock
(For general use)
10
WARRANTY
Security rope
M8 Screw
Roll pin
4x25 Wood
4X10 Screw
screw
2
1
Cap nut
Manual
1
1
BP or
12V dc
TEL/DAS
24V dc or 48V dc
NC C NO
-
+
+
-
Standard
CDVI IBÉRICA
[SPAIN - PORTUGAL]
Phone +34 (0)935 390 966
www.cdviberica.com
CDVI ITALIA
Phone +39 0321 90 573
Fax: +39 0321 90 8018
www.cdvi.it
Fixing plate
Magnetic lock
Cap nut
MOUNTING RECOMMENDATIONS
6
Armature plate
- It is vital that the magnetic lock and armature
plate are securely fi xed to their supports.
- The magnetic lock and the armature plate must
be aligned.
- The armature plate must be mounted "fl oating"
around the central mounting screw to
compensate for any misalignment of the door
Security rope
The security rope
Throughout its life, the magnetic lock is subject to an
accumulation of repeated shocks and stresses at the
fi xing points on the frame, frequencies of opening/
closing, (attempt to open a locked door and attempts
at vandalism) which can cause it to become detached
from the support when it is opened. In order to avoid
the risk of the electronic lock block falling, install the
two safety cables supplied to guarantee the safety of
the users (see diagram above).
CDVI TAIWAN
Phone +886 (0)42471 2188
www.cdvichina.cn
CDVI CHINA
Phone +86 (0)10
84606132/82
www.cdvichina.cn
EN
Security rope
Armature plate
Steel washer
Rubber washer
AMA3 (option)
Security rope
CDVI MAROC
Phone +212 (0)5 22 48
09 40
www.cdvi.ma
CDVI POLSKA
Phone +48 12 659 23 44
www.cdvi.com

Publicité

loading

Sommaire des Matières pour CDVI V3SR1248

  • Page 1 Manufacturing Access Control since 1985 V3SR1248 - FREE VOLTAGE 300 kg Mount Electromagnetic lock (For general use) PRODUCT PRESENTATION Fixing plate NF S61-937 - PV n° SD190043 Surface mount High corrosion resistance Magnetic lock Security rope YEAR No mechanical wear...
  • Page 2 Manufacturing Access Control since 1985 V3SR1248 - FREE VOLTAGE Ventouse électromagnétique applique 300 kg (Utilisation standard) INSTALLATION PRÉSENTATION DU PRODUIT Plaque de montage Presse-étoupe NFS 61937 - PV n° SD190043 (si utilisation Montage en applique conforme Résistance à la corrosion...
  • Page 3 TEL/DAS 48V DC compenser un mauvais alignement de la porte. La norme NFS61-937 exige d’alimenter la V3SR1248 avec une alimentation Filins de sécurité 24 ou 48V DC. (fi xations sur ventouse et bâti) Sélection automatique de la tension.