Ventilation Fan
MODEL: 8814R
SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE
WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT.
IMPORTANT SAFETY INSTRUCTIONS
    WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A.   U se this unit only in the manner intended by the manufacturer. 
If you have questions, contact the manufacturer.
B.   B efore servicing or cleaning unit, switch power off at service 
panel and lock service panel to prevent power from being 
switched on accidentally. 
When the service disconnecting means cannot be locked, 
securely fasten a prominent warning device, such as a tag, to 
the service panel.
CAUTION:
    For general ventilating use only. Do not use to exhaust 
hazardous or explosive materials and vapors.
INSTALLATION INSTRUCTIONS
   
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A.   I nstallation work and electrical wiring must be done by 
qualified person(s) in accordance with all applicable codes and 
standards, including fire-rated construction.
B.   S ufficient air is needed for proper combustion and exhausting 
of gases through the flue (chimney) of fuel burning equipment 
to prevent back drafting. Follow the heating equipment 
manufacturer's guideline and safety standards such as those 
published by the National Fire Protection Association (NFPA), 
and the American Society for Heating, Refrigeration and 
Air Conditioning Engineers (ASHRAE), and the local code 
authorities.
C.   W hen cutting or drilling into wall or ceiling, do not damage 
electrical wiring and other hidden utilities.
D.   D ucted fans must always be vented to the outdoors.
E.   I f this unit is to be installed over a tub or shower, it must be 
marked as appropriate for the application.
F.   N EVER place a switch where it can be reached from a tub or 
shower.
WARNING: To reduce the risk of fire or electric shock, do not 
use this fan with any solid-state speed control.
• Not for use in kitchens.
•   S uitable for use over tub or shower when installed in a GFI 
(or GFCI) Protected Branch Circuit.
•   D o not install in a ceiling insulated to a value greater than R-40.
•   T he exhaust fan consists of the housing, power unit/blower 
assembly (motor, wheel, mounting plate,) grille and duct collar.
TO REGISTER THIS PRODUCT, VISIT WWW.NUTONE.COM
READ & SAVE THESE INSTRUCTIONS!
HOUSING
SLOTS
TABS
FOR BEST RESULTS
When installing the exhaust fan in a new construction site, 
install housing during the rough-in construction of the building. 
The blower unit and grille should be installed after the finished 
ceiling is in place.
    To install the exhaust fan in an existing finished building 
requires an accessible area (attic or crawl space) above the 
planned location.
PLANNING DUCTWORK AND WIRING
DUCTWORK
1.   U se 4" round duct.
2.   P lan to run duct from discharge opening of fan to the outside. 
For best fan performance, make duct run as short as possible.
3.   U se optional NuTone ducting accessories as needed. Refer 
to your NuTone catalog for a complete listing of available 
accessories.
WIRING
    Plan to run 120vAC house wiring (with ground) from power 
source, through a standard wall switch to junction box in fan 
housing.
INSTALLATION INSTRUCTIONS
POWER UNIT/
BLOWER
ASSEMBLY
GRILLE
DUCT
COLLAR
FIGURE 1

Publicité

loading

Sommaire des Matières pour NuTone 8814R

  • Page 1 TO REGISTER THIS PRODUCT, VISIT WWW.NUTONE.COM INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS! Ventilation Fan DUCT COLLAR MODEL: 8814R HOUSING SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT. IMPORTANT SAFETY INSTRUCTIONS     WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC...
  • Page 2 2.   P ull wire through access hole and into junction box. 3.   R efer to Figure 4. Use approved wire nuts to connect  house supply wires to fixture wires as follows: white to  STANDARD WALL SWITCH white; black to black. Connect green or bare ground wire   (NOT INCLUDED) OR SWITCH to green ground lead. OPTIONAL NUTONE SPEED CONTROL POWER/BLOWER UNIT INSTALLATION 1.   P lace power/blower unit into housing so that mounting  120vAC, 60 Hz plate’s tabs insert into slots in housing. HOUSE POWER EARTH GROUND 2.   P ress other end of mounting plate down until it is firmly ...
  • Page 3 FIGURE 5 One Year Limited Warranty WARRANTY OWNER:   Broan-NuTone  warrants  to  the  original  consumer  purchaser  of  its  products  that  such  products  will  be  free  from  defects  in  materials  or  workmanship  for  a  period  of  one  (1)  year  from  the  date  of  original  purchase. ...
  • Page 4 Ventilateur de ventilation COL DE GAINE BOITIER MODÈLE: 8814R Prévu U.L. pour utilisation dans une cabine de douche ou de salle de bain lorsque la dérivation est protégée avec GFCI. IMPORTANTES DIRECTIVES DE SÉCURITÉ AVERTISSEMENT: POUR RÉDUIRE LES RISQUES D’INCENDIE, DE CHOCS ÉLECTRIQUES OU DE BLESSURES, RESPECTER CE...
  • Page 5 1.    A mener un câble de 120 V CA (avec terre) de l’interrupteur mural  STANDARD BOITER à l’emplacement du ventilateur. Voir Figure 4. (NON FOURNI) OU D’INTERRUPTEUR 2.    P lacer un raccord agréé dans le trou d’entrée du câblage. COMMANDE DE VITESSE 3.    T irer les câbles par le raccord jusque dans le boîtier de  NUTONE EN OPTION raccordement. Serrer le raccord. 4.    V oir Figure 4.  Utiliser des connecteurs agréés pour raccorder  les câbles d’alimentation générale aux câbles du l’élément: le  COURANT DOMESTIQUE blanc avec le blanc, le noir avec le noir. Raccorder le câble de  120vCA, 60 Hz TERRE terre vert ou nu à la vis verte de mise à la terre.
  • Page 6 D’ADAPTATION À UN USAGE PARTICULIER. Pendant cette période d’un an, Broan-NuTone procédera au remplacement ou à la réparation sans aucuns frais, mais à sa propre discrétion, de tout produit ou pièce jugé défectueux dans le cadre d’une utilisation normale. CETTE GARANATIE NE VISE PAS LES DISPOSITIFS D’AMORCAGE NI LES TUBES DES LUMINAIRES FLUORESCENTS.
  • Page 7 D.   L os ventiladores entubados siempre deben estar ventilados hacia  1.    U se ductos redondos de 4 pulgadas (10 cm). el exterior. 2.    P lanee correr la tubería desde la apertura de escape del  E.   S i la unidad se va a instalar encima de una bañera o ducha, aquélla  ventilador hasta el exterior. Para un mejor funcionamiento del  debe estar señalada como apropiada para la aplicación. ventilador, haga que el largo de la tubería sea lo más corto  F.   N o coloque NUNCA un interruptor donde pueda ser alcanzado  posible. desde la bañera o ducha. 3.    U se accesorios de tubería opcionales NuTone si fuera  ADVERTENCIA: Para reducir el riesgo de incendio o choque  necesario. Vea su catálogo de NuTone para una lista completa  eléctrico, no utilice este ventilador con ningún dispositivo con control de  de accesorios disponibles. la velocidad de estado sólido. • No lo utilice en cocinas. ALAMBRADO •   A propiado para ser utilizado sobre la bañera o la ducha cuando se    Planee establecer el alambrado de 120v c.a. (con conexión a  instala en un circuito derivado protegido GFI (o GFIC).
  • Page 8   Todo alambrado debe concordar con los códigos locales y deben INCLUIDO) O CONTROL INTERRUPTOR tener una apropiada conexión a tierra. DE VELOCIDADES 1.    C orra alambres de 120v c.a. (incluyendo a tierra) desde el interruptor  OPCIONAL DE NUTONE de pared hasta donde se encuentra el ventilador. 2.    C orra el alambre a través del agujero de acceso y hacia adentro de  la caja de conexiones. FUENTE DE ELECTRICIDAD DE TERRA LA CASA DE 120v c.a., 60 Hz...
  • Page 9 MERCHNTIBILIDAD O ADAPTABLES A UN PROPÓSITO EN PARTICULAR. Durante este período de un año, Broan-NuTone reparará o reemplazará a su opción y sin costo, cualquier producto o parte que se encuentre defectuoso bajo condiciones normales de uso y servicio. ESTA GARANTÍA NO CUBRE A LOS ARRANCADORES PARA LÁMPARAS FLUORESCENTES O A LOS TUBOS FLUORESCENTES, FILTROS, DUCTOS, TAPAS DE TECHO, TAPAS DE PARED Y OTROS ACCESORIOS PARA CANALIZACIÓN.
  • Page 10 SERVICE PARTS Model 8814R KEY NO. PART NO. DESCRIPTION 1  101255-000  MOTOR MOUNTING PLATE 2  32787-000  MOTOR ISOLATION MOUNT 3  32788-000  GROUND CLIP 4  100599-000  MOTOR 5  100603-000  BLOWER WHEEL 6  30652-000  DUCT ADAPTER ASSEMBLY 7  44208-000  GRILLE AND SPRING ASSEMBLY 8  99270982  RECEPTACLE 9  97017707  POWER UNIT ASSEMBLY Broan-NuTone LLC    Hartford, Wisconsin    www.nutone.com    888-336-3948 99044122A...