7
7C
7B
7A
7D
7E
7B
7 HANDLE ATTACHMENT
Place Plastic Seal Rings (7A) against the bottom of Handle Hubs (7B). Connect Handles
(7C) onto Valve Adapters (7D) and be sure Valves and Levers are in the "OFF" position.
Secure handles by holding the Lever (7E) in place and tighten the Hubs (7B) by rotating
them in a clockwise direction.
To remove handles, rotate Hubs (7B) in a counterclockwise direction.
8
8B
8D
8E
8 SPOUT BODY INSTALLATION
Apply plumber's putty into groove on bottom of Gasket (8A) per manufacturer's
recommendations. Place Gasket (8A) under base of Spout Body (8B). From above
sink, insert Mounting Shank (8C) through center hole of sink.
From underneath sink, place large Washer (8D), and Locknut (8E) onto Mounting Shank
(8C). Tighten faucet firmly to sink.
ENGLISH
7C
7B
7A
7D
8C
8A
9
9 SIDE SPRAY INSTALLATION
From above sink, insert Hose Guide (9A) through Seal Ring (9B) and sink hole. Insert Side
Spray Hose (9C) through Hose Guide (9A). From underneath sink, secure Hose Guide
(9A) by screwing Locknut (9D). Hand tighten.
Caution: do not over tighten!
10
10B
10B
10B
10D
10 HOSE CONNECTION TO SPOUT BODY
From underneath sink, insert the Center Connector (10A) onto Spout Shank (10B).
Slide Clip (10C) into Center Connector Holes (10D), to secure unit.
When installing without side spray, a Plug Connector (10E) 972-001 must be used and
is to be ordered separately.
3
9C
9A
9B
9D
10A
10E