Pre-blinking time
Before any gate movement, blinker will be activated for t.PrE time, to
warn about the incoming motion.
Gate Direction
This menu allows to invert the opening direction of the gate without
swapping motor wires and limit switch ones.
dx
the gate opens rightwards
Sx
the gate opens leftwards
WARNING: "opening direction of gate" means the direction you
see from the inside.
Motor power
This menu allows adjusting the motor power.
The displayed value is the percentage of max. motor power.
Start off
When the gate is standstill and it begins moving, the initial inertia must
be faced, therefore, if your gate is quite heavy, it could not move.
In case the SPUNTO (pickup) function is activated, for the first 2
seconds of motion of each door, the control unit will ignore Pot value
and it will give motor the maximum power command in order to
overcome the gate inertia.
Soft start (slowed down)
In case this function is enabled, during the first seconds of motion of
the gate, the control unit will give motor a reduced power command,
for a softer start.
34