Cod. 970030 V04_18
Change access mode
* (Master) #
4 0 #
4 1 #
4 2 #
4 3 (2-9) # (Multi-card, PIN. Upon presenting 2 to 9 valid cards or pins the door opens)
*
Activate or deactivate the door sensor and adjust acoustic and visual response. All in ON by default
Door Sensor
* (Master) #
5 0 # (deactivated by default)
5 2 # (activate Door Sensor)
*
Activate or deactivate the Alarm.
Alarm
* (Master) #
6 0 #
(deactivated by default)
6 1 #
(activate alarm. Disables the reader for 10 minutes upon presenting 11 invalid cards or pins)
6 2 #
(activa alarma y la salida auxiliar (Alarm-) durante 1 minutos o hasta que se presente una tarjeta
o pin válido, upon presenting 11 invalid cards or codes)
*
Restore default values (Users are not removed) and master cards programming.
1. Switch off the device.
2. Connect GND and Bs.
3. Switch on the device.
4. You will hear 2 beeps, the LED changes to another more orange tone.
1. Remove the bridge or stop pressing the exit button and present two cards, it will be the 1st master
Add and the 2nd master Delete.
2. Keep the bridge between GND and Bs or the Exit button pressed for at least 10 seconds more until
you hear a beep, and see that it returns to standby, it is restored to the factory settings.
Maintenance
FACTORS INFLUENCING THE OPERATING DISTANCE
Orientation of the proximity key. Faulty reader supply. Interference on the 125khz and 13.56 MHz band.
CE DECLARATION OF CONFORMITY
Hereby, FERMAX ELECTRONICA, S.A.U., declares that this KEYPAD RESISTANT REF. 5293, is in compliance with the
essential requirements of Directive RED 2014/53/UE and Directive RoHS 2011/65/UE. See website
www.fermax.com. FERMAX Avd. Tres Cruces, 133, 46017 Valencia, Spain.
http://docweb2.fermax.com/docs/deconformidad/EN/F05293.pdf
(Only card)
(Card+ PIN)
(Card or PIN (by default))
Sound and LED keypad
* (Master) #
7 0 # OFF
7 2 # OFF
7 4 # OFF
*
7 1 # ON
(Sound)
7 3 # ON
(LED standby)
7 5 # ON
(Back lighting)