REPLACEMENT ELECTRODE T-CELL:
IMPORTANT: NEW MENU SETTINGS MAY BE REQUIRED WHEN INSTALLING.
The CAS replacement T-CELL is designed to match or exceed the performance and longevity of the
HAYWARD™or GOLDLINE™ T-CELL or GLX-CELL electrode for pools up to 40,000 gallons. When
replacing an existing T-CELL or GLX-CELL, no re-configuration is necessary.
Yo
CELL with a new control unit.
Incorrect configuration will cause:
1. Improper operation,
2. Inaccurate salt readings and
3. Possible system shutdown.
CONFIGURATION IS REQUIRED WITH THESE MODELS:
AQR (AquaRite-all 2009 or later) - rmware version 1.5 or later
AQR-PRO (AquaRitePro)
PL-P-4 (ProLogicP4)
PL-PS-x (ProLogicPS)
AQ-LOGIC-P-4 (ProLogicP4)
AQ-LOGIC-PS-x ProLogicPS)
CONFIGURATION IS NOT REQUIRED WITH THESE MODELS:
AQ-RITE (AquaRite-2008 and earlier) - rmware earlier than version 1.5
AQ-RITE-XL (AquaRiteXL)
CONFIGURATION FOR AQR MODELS
1. Slide the Main Switch to the "Auto" position
2. Push the Diagnostic button repeatedly until "t-xx" appears on the display ("t-15" is the factory default)
If "t-15" is displayed
3. To change cell type, slide the Main Switch from "Auto" to "Super Chlorinate" and back to "Auto"
Repeat this process until the "t- "
4. Push the Diagnostic button to exit
CONFIGURATION FOR AQR-PRO:
1. Access the Settings Menu by pushing the "Settings" buttons
2. Push ">" until "Chlor.Config" is displayed, then push "+"
3. Push ">" repeatedly until "Cell Type" is displayed
4. Push "+" o r "-" until "T-CELL-XX" required model is displayed
5. Exit Settings Menu by pushing the "Info" button
CONFIGURING FOR AQ-LOGIC-P-4, AQ-LOGIC-PS-X, PL-P-4 OR PL-PS-X:
1. Enter the Configuration Menu
2. Push ">" until Chlor.Config is displayed, then push "+"
3. With the Chlorinator Enabled, push ">" repeatedly until "Cell Type" is displayed
4. Push "+" or "-" until "T-CELL-XX" required model is displayed
5. Exit Settings Menu by pushing the "Menu" button
CONTACT:
MENU SETTINGS
gurations as per the information below, prior to using the replacement
:
skip to step 4
displayed
FO@CRYSTALAS.COM if your model version is not listed.