KLASS Fan ARIME LIGHT Manuel D'utilisation page 19

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
5
Slide the remote controller receiver
unit into the slot on the mounting
bracket.
6
Wire-in the remote controller receiverunit as shown in the figure below. Terminal
block on the mounting bracket must be used between the receiver output wire
and the motor wires. Terminal block provided separately along with the remote
controller pack must be use to connect between the supply wire.
To Light
To motor
wire
Remote receiver
To fan
Canopy
Hole for temperature
sensor
For light
Red
Brown
Orange
Brown
Power supply live-wire
Blue
Power supply neutral-wire
Yellow/Green
Ground wire
Temp. wire
Black wire
Antenna wire
17
Power supply
Temp. wire
Canopy