Case Batch Mode:
Pump doses the selected quantity when UP button is pressed or when a pulse is read on input (other pulses are
ignored when pump is dosing) or if trigger/s signals are selected, when a valid trigger/s signals is read on input.
If time selected for dosing is too short, pump doses at the maximum flow rate.
Programming
Batch MODE
Time
 
Batch MODE
Qty
 
Paragraph 6
Makes it possible to set the Pump Functions as follow:
Pump functions
N:1 Mode
0000137630
 
 
 
1sec
 
 
 
 
0.001 L
 
Pump functions
Manual Mode
Pump functions
Batch Mode
Pump functions
1:N Mode
Rev. 2.0
The pump doses in proportion to an external signal (i.e.:
impulse launch counter). In this case, it is possible to set
the quantity to be dosed in l and the time within which to
complete dosage.
Dosage can be started manually by pressing the
or by using a remote control. The
dosage. The dosage already made can be reset by
pressing the
key again.
The quantity to be dosed can be modified during operation,
by pressing the
increase the flow, or the
Makes it possible to set:
Time= the time within which to complete dosage in
second
Qty= the quantity to be dosed in liter
 
Pump
Pump functions
Functions
mA Mode
Setting
Menu
Pump functions
PPM Mode
Operation
key interrupts
key, or started again by pressing the
keys at the same time to
keys to decrease.
key,
12