INSTALLATION
Ring
TM
or the threads on the tank shell
as this may collect grit and make re-
moval difficult.
3.
Install the O-ring in the tank lid as-
sembly O-ring groove. Be sure that
the 0-ring is clean and not twisted.
4.
Place the Posi-Ring
TM
squarely
over the tank shell threads and rotate
COUNTERCLOCKWISE until the ring
falls into the threads; then rotate it
CLOCKWISE until it is securely lat-
ched.
5.
Follow instructions in the »Initial
Startup« section of this manual.
CARTRIDGE CLEANING PROCEDURE
When to Clean the Filter: The filter
cartridge should normally be cleaned
when the pressure gauge reading in-
creases 0,7 bar over the start-up
pressure.
Follow all steps in the »Disassembly«
section of this manual.
The filter cartridge should be removed
and cleaned when pressure rises
more than 0,7 bar above start-up
pressure.
NOTICE:
When sanitizing your pool using
PHMB (polyhexamethylene biquanide
based) cleaners, use only PHMB
cleaners to clean the cartridge. When
using PHMB sanitizers, the filter
cartridge MUST be cleaned more
thoroughly and frequently than for a
pool using chlorine. Follow manufac-
turer's instructions carefully. Use of
any other type of cleaners with PHMB
pool sanitizers wiII void the filters
warranty.
1.
Remove the drain cap and flush alI
foreign material from the inside of the
tank before removing the filter
cartridge.
2.
Allow the tank to drain.
3.
Lift out the cartridge and hose it
down thoroughly. Spray the entire
cartridge surface. Allow cartridge to
drain.
4.
Inspect the cartridge. If necessary,
repeat the washing operation. If the
cartridge is damaged, replace it.
5.
Follow all steps in the »Assembly«
and »Initial Startup« sections of this
manual. NOTICE: When this procedu-
re no longer adequately cleans the
cartridge, discard the cartridge and
replace it with a new one.
SYSTEM INSPECTION
General:
NOTICE:
DO NOT use solvents to clean the fil-
ter; solvents may damage plastic
components in the system.
NOTICE:
Open the air release valve and bleed
all air from the filter each time the
pump is stopped and restarted.
Weekly Inspection:
1.
Remove debris from the pool skim-
mer basket.
2.
Stop the pump; open the air release
valve to release all pressure.
3.
Remove the pump trap cover and
basket; remove debris.
4.
Check the pump for leaks. If found,
see the pump owner's manual.
5.
Replace the trap basket and the
cover. Tighten the cover securely
hand tight. DO NOT use a lid wrench
to tighten it.
6.
Start the pump. When the filter air
release valve runs a solid stream of
water, close the valve.
- POSI-CLEAR™ -
7.
When the system has returned to
normal operation, check the filter
pressure. If the filter pressure is
0,7 bar or more higher than the initial
startup pressure, the filter needs clea-
ning. See »Cartridge Cleaning Proce-
dure«.
WINTERIZING
NOTICE:
Protect the filter from freezing. Allo-
wing the filter to freeze wiII damage it
and wiII void the warranty. If possible,
take the system indoors for storage.
1.
Clean the filter according to in-
structions before winterizing.
2.
Stop the pump.
3.
Open the air release valve; open
any system valves.
4.
Remove the drain plugs from the
trap, pump, and filter.
5.
Gravity drain system and filter as
far as possible.
6.
Disassemble the filter (follow in-
structions under »Filter Disassembly«,
Page 5). Remove the filter cartridge
and store it in a warm, dry area.
7.
Cover the filter with plastic or tar-
paulin to prevent water entrance and
freezing.
13