OPERATION

1.25 Cleaning Pump

After pumping water containing a large amount of dirt or
debris, clean out inside of pump housing.
(a)
1. Remove drain plug
any water left in pump.
2. Loosen the four knobs holding the pump cover
and remove cover.
3. Clean out dirt and debris. Inspect impeller and volute
insert for wear.
!
WARNING
The impeller may develop sharp edges. Use care
when cleaning around impeller to prevent getting
cut.

1.26 Cleaning Fuel Strainer

Turn fuel valve off. Remove strainer cup
(e)
strainer
. Wash them thoroughly in a nonflammable
solvent. Dry them and install. Turn fuel valve on and
check for leaks.