Connection With The Mains; Operation; Cleaning And Maintenance; Replacing The Fuse - EuroLite Snow 3001 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connection with the mains

Connect the device to the mains with the power plug. The occupation of the connection cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green Earth
Attention! The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a minimum
opening of 3 mm at every pole has to be included in the permanent electrical installation. The device must only be
connected with an electric installation carried out in compliance with the IEC standards. The electric installation must be
equipped with a Residual Current Device (RCD) with a maximum fault current of 30 mA

OPERATION

Press the button on the remote control to emit snow.
CAUTION: The escape nozzle will heat up during operation. Therefore do not touch the nozzle until it
has cooled down completely.

CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents! There are no serviceable parts inside the device except for the fuse. Maintenance and
service operations are only to be carried out by authorized dealers.

Replacing the fuse

If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder with a fitting screwdriver from the housing (anti-clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts. If the power supply cable of this device
becomes damaged, it has to be replaced by authorized dealers only in order to avoid hazards. Should you
have further questions, please contact your dealer.

TECHNICAL SPECIFICATIONS

Power supply:
Power consumption:
Tank capacity:
Fuse:
Dimensions (LxWxH):
Weight:
Please note: Every information is subject to change without prior notice. 27.11.2013 ©
International
L
N
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
230 V AC, 50 Hz
410 W
0.5 l
F 4 A, 250 V
350 x 190 x 225 mm
3 kg
13/19
.
00080396.DOCX, Version 2.2

Publicité

Table des Matières
loading

Table des Matières