Installation Notes
LPS40 Series
Input Specifications
Input range
85 VAC to 264 VAC
120 to 370 VDC
Frequency
47 - 440 Hz
Inrush current
< 18 A peak @ 115 VAC
< 36 A peak @ 230 VAC
Input current
1 A max. (RMS) @ 115 VAC
Efficiency
70% typical at full load
EMI filter
Meets FCC Class B
CISPR 22 Class B
(includes EN55022 class B
and VDE 0878 PT3 class B)
Electromagnetic
Meets IEC801-2 level 3,
Compatibility
and IEC801-5 level 3
Safety ground
< 0.5mA @ 50/60Hz, 264VAC
leakage current
input
Environmental
Operating temperature: 0°C to 50°C ambient;
derate at 2.5% / °C from 50°C to 70°C
Storage temperature:
Thermal regulation:
MTBF: > 100,000 hours at full load and 25°C
ambient conditions
Notes (refer to table)
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor.
Mating Connectors
AC Input:
Housing
DC Output:
Housing
Contacts:
18/24 AWG Molex 08-50-0106
Remote Sense: Housing
Contacts:
22/30 AWG Molex 08-50-0114
Notes
1 Specifications subject to change without notice.
2 All dimensions are in mm and (inches).
3 Mounting holes M1 and M2 should be earthed for EMI purposes.
4 Output Common capacitivily coupled to M2 earth.
5 Mounting hole M1 is safety earth connection. This power supply
must be earthed for safe operation via mounting hole M1 or 1/4"
blade with Faston connector.
6 Weight 0.23kg/0.5 lb.
Warning: Hazardous mains voltages present within this
unit. Primary heatsink is live. Please see enclosed 'Astec
Installation and Operating Instructions'. Use of optional
cover kit is recommended for safe operation.
40 Watt
Single Output
IEC801-4 level 3
-40°C to 85°C
± 0.04% / °C
Molex 09-91-0300
Molex 09-91-0600
Molex 22-01-2025
Output Specifications
Maximum
wattage
Adjustment
range
Hold-up time
Overload
protection
Overvoltage
protection
Safety
VDE
0805/EN60950 (IEC950)
UL
UL1950
CSA
CSA 22-2-234 Level 3
NEMKO
EN 60950/EMKO-TUE (74-sec) 203
BABT
EN60950/BS7002
CB
Certificate and report
This product is CE marked following
the provisions of the Low Voltage
Directive 73/23/EEC
(or 26-03-4030)
(or 26-03-4061)
(or 08-58-0189)
40 W for convection; 55 W with
30 CFM forced air except LPS41-
26W conv., 36W forced air
– 5%, +10% minimum, via voltage
adjustment potentiometer
20 ms at full load and 115 VAC
nominal line
Short circuit protection. Auto
recovery. Total power limited @
110% to 145% above peak rating
5V output: 5.7 to 6.7 Vdc. Other
outputs 10 to 25% above nominal
output; recycle AC to reset
Remote Sense
SK201 pin1 –sense
pin2 +sense
This power supply has a connector for
output remote sense. This can be used to
compensate for cable voltage drops of up
to 0.5V. If this feature is not used the
power supply reverts to internal local
sense. Protected against reverse
connection.
Enclosure
Enclosure kit available-
(LPX40 Cover Kit)
Overall dimensions in enclosure -
150 (5.9) x 98 (3.86) x 38 (1.5)
Total power in enclosure derates to:- 25W
convection, 40W with 30CFM forced air
Fusing
Input fuse 2.5A 20mm Quick Acting HBC
mains fuse - only replace with same type
and rating to maintain safety standards.