A. OUTSIDE TOP EXHAUST
INSTALLATION OVERVIEW
A1. Attach Mounting Plate to Wall
A2. Prepare Top Cabinet
A3. Adjust Blower Exhaust
A4. Install Exhaust Adaptor
A5. Mount the Kitchen Hub™
A6. Connect Ductwork
A7. Finalize Installation
ATTACH THE MOUNTING PLATE
A1
TO THE WALL
A
C
Attach the plate to the wall using toggle bolts. At
least one wood screw must be used to attach the
plate to a wall stud. Recommended locations on the
mounting plate are indicated by A, B, C and D.
1. Remove the toggle wings from the bolts.
2. Insert the bolts into the mounting plate through
the holes designated to go into drywall and
To use toggle bolts:
Toggle Wings
Mounting
Plate
Wall
3. Place the mounting plate against the wall and
insert the toggle wings into the holes in the wall to
mount the plate.
NOTE: Before tightening toggle bolts and wood
screw, make sure the tabs on the mounting plate
touch the bottom of the cabinet when pushed
flush against the wall and that the plate is properly
centered under the cabinet.
18
Installation Instructions
B
D
Spacing for Toggles More
Than Wall Thickness
Toggle
Bolt
Bolt End
Mounting Plate
(Vertical Duct)
ATTACH THE MOUNTING PLATE
A1
TO THE WALL (Cont.)
CAUTION
Be careful to avoid pinching
fingers between the back of the mounting plate
and the wall.
4. Tighten all bolts. Pull the plate away from the wall
to help tighten the bolts.
A2
USE TOP CABINET TEMPLATE
FOR PREPARATION OF TOP
CABINET
You need to drill holes for the top support screws and
a hole large enough for the power cord to fit through,
and a cutout large enough for the exhaust adaptor.
TEMPLATE.
TOP CABINET TEMPLATE.
CAUTION
Wear safety goggles when
drilling holes in the cabinet bottom.
49-2000492 Rev. 2