G
B
TRANSMITTER SETTINGS AND CONNECTIONS
J6
Terminals for the connection of the clean contact of the mechanical or inductive
safety edge (N.C. or N.O.).
SWTX
Micro-switches for coordination and identification
JP3
Safety edge enabling/disabling jumper (standard jumper not inserted for
unconnected safety edge. Disable the jumper if a safety edge is connected)
JP4
Safety edge contact selector jumper N.O./N.C. (factory setting N.C.)
JP5
Range selector jumper 13/25 m (factory setting 25 m)
BAT
Alkaline batteries 2 x AA 1,5V
DLTX
Green LED function indicator
STANDARD POSITIONS OF THE JUMPERS
BAT
JP5
JP3
JP4
NOTE: EACH TIME A NEW JUMPER CONFIGURATION IS USED IT IS NECESSARY TO TURN OFF AND TURN ON POWER TO BOTH THE TRANSMITTER AND THE RECEIVER.
REFERENCE TO STANDARDS FOR AUTOMATIC GATES AND DOORS
The installer must ensure that the installation of the NOVA Wi-Fi photocells is performed only
in the presence of further protection as specified by standard EN12453 in 5.5.1. (general
protection requirements).
RIB MAY NOT BE HELD RESPONSIBLE FOR DAMAGES CAUSED BY IMPROPER, WRONG
OR UNREASONABLE USE.
Usage restrictions: The NOVA Wi-Fi photocells cannot be used on devices excluded by the
application of the EN12978, such as:
- protection devices for the installation on doors used for a different purpose to those ones
used for pedestrian or veheicle access, covered by the norm which principal intent is that
of allowing a safe access to industrial, commercial, public and commercial sites. Some
examples of excluded accesses can be: sluice gates, dams, lift doors, vehicles' doors,
doors used mainly to restrain animals, theatre curtains, railways barriers, barriers used
only for vehicles.
- Devices used only fo the standard control and for the stopping, including the emergency
stopping, of motorized doors.
- Safety systems and safety devices used on machineries different from doors.
ATTENTION: Any possible modification of the device, or of the configuration of the same
cannot be carried out without the clear authorization by the manufacturer or, by the local
authorized dealer.
RECEIVER SETTINGS AND CONNECTIONS
J7
SWRX
S3 PROG. TX
JP6
JP7
JP8
BAT
DLRX
DLTX
SWTX
J6
The installer of the safety device must make sure that the end user know the following:
- That the safety devices must be made known to all appropriate people.
- That the passages to reach the devices must be kept clear from any obtsacle.
- About the procedures for cleaning so to avoid the dangerous building up of material.
- The possible details for a restart of the system after an emergency or accidental stop
caused by the control system.
Any modification of the project or, of the configuration of the device, without discussing it
first with the manufacturer or with the local autorized dealer can cause dangerous situations.
USES
NOVA Wi-Fi photocells communicate constantly and exclusively with the MASTER Wi-Fi card
and completely meet the active security demands of all types of automatic opening systems.
WARNING: If you remove the power of the MASTER Wi-Fi for a long time, the TOUCH
Wi-Fi safety edges and the NOVA Wi-Fi photocells will exhaust faster than normal the
charging of their batteries. Keep the MASTER Wi-Fi always properly fed to ensure a
period of three years for the batteries-life, as stated by RIB.
If for instance, the power to the system is cut off every night, the photocells
and the safety edges will regularly and constantly search for the MASTER
Wi-Fi without finding it. Therefore, the life span of the batteries may be
reduce to less than one year.
14
Terminals for the connection of the clean contact of the mechanical or
inductive safety edge (N.C. or N.O.).
Micro-switches for coordination and identification
Push-button for memorization and alignment
Safety edge enabling/disabling jumper (standard jumper not inserted
for unconnected safety edge. Disable the jumper if a safety edge is
connected)
Jumper wire for photocell or safety edge selection (factory setting
contacts closed)
Safety edge contact selector jumper N.O./N.C. (factory setting N.C.)
Alkaline batteries 2 x AA 1,5V
Red LED indicating correct power and infrared signal alignment
STANDARD POSITIONS OF THE JUMPERS
BAT
JP7
JP6
JP8
S3
DLRX
SWRX
J7