NOMINAL: Changes the ESDONI to NOMINAL status.
OFF: Changes the ESDONI to DISCONECTED status.
REDUCED 1: Changes the ESDONI to REDUCED 1 status.
REDUCED 2: Changes the ESDONI to REDUCED 2 status.
REDUCED 3: Changes the ESDONI to REDUCED 3 status.
REDUCED 4: Changes the ESDONI to REDUCED 4 status.
Each ESDONI status change requires confirmation via the keypad in
order to avoid false activations as shown in the following example:
Xeolum menu
ESDONI
> Parameters
> config
program
> Nominal
> off
WANT TO CHANGE
OK
> cancel
If OK is entered, the ESDONI will change its status to PROGRAM.
2) PARAMETERS. This menu allows the display of all configuration or
measurement parameters, providing more complete information than
the status screens.
DATE/TIME
Time/date
Time; 14;56;05
date; 12/05/12 MO
DAWN; 07;06;00
POSITION
Position
Lat; 40.528183
Long; -3.656806
MODEM
MODEM status
MODEM; 6
IP; 176.81.199.205
SERV; 70.210.110.20
CONNECTION; 1
• Modem status:
1 to 4 –modem start-up status.
El 5 – waiting for GSM network registration.
El 6 – registered in the GSM network.
• Internal modem temperature: in ºC.
• GSM coverage: in dBm. Optimum coverage greater than -85
dbm.
• IP: dynamic IP assigned to the equipment.
• SERV: WEB platform server address.
• CONNECTION: Server connection status. 1 – connected / 0 –
disconnected.
esdoni
Program
Time; 14;56;05
date; 12/05/12 Mo
DAWN; 07;06;00
DUSK; 21;17;00
Internal MODEM temperature
GSM coverage
T34
C-65
Connection status
ANALYZER. This will display the same information as the status
screens.
- VOLTAGE
- CURRENT
- ACTIVE POWER
- REACTIVE POWER
- POWER FACTOR
- ACTIVE ENERGY 1
- ACTIVE ENERGY 2
ESDONI STATUS. Displays the status of the three ESDONI phases
(NOMINAL, START-UP, REDUCED 1 to 4, and SWITCHED OFF).
esdoni Status
Phase r
v;0.00
ESTATE; ---
Alarm; DISCONECTED
ESTATE; ---
Alarm; DISCONECTED
Phase s
v;0.00
ESTATE; ---
Phase s
v;0.00
ESTATE; ---
Alarm; DISCONECTED
Phase t
v;0.00
Alarm; DISCONECTED
Phase T
v;0.00
Status; ---
Alarm; DISCONECTED
INPUTS/OUTPUT. This menu shows the input and output statuses.
Inputs/outputs
Inputs
0 0 0 0 0 0 0 0 0 0
outputs
0 – switched off / 1 – switched on.
3) CONFIGURATION.
This
configuration.
Before allowing access to this menu, the XEOLUM will request an
access password. When it is entered, the first password digit will flash
(step 1), press
and the first password number can be entered
with the
and
keys (step 2). When the desired number has
been entered (step 3), the next digit is selected with the
keys (step 4). When the entire password has been written (step 5) it is
confirmed with
and the edition mode is exited (step 6). The
or
key is used to select the option OK and
Step 1
password
0000
> OK
> CANCEL
Step 3
password
5000
> OK
> CANCEL
Phase r
v;0.00
ESTATE; ---
Alarm; DISCONECTED
Phase s
v;0.00
Alarm; DISCONECTED
Phase s
v;0.00
ESTATE; ---
Alarm; DISCONECTED
ESTATE; ---
Alarm; switched off
Phase t
v;0.00
ESTATE; ---
Inputs
0 0 0 0 0 0 0 0 0 0
outputs
0 0 0 0
modifies
the
XEOLUM
operational
is pressed (step 7).
Step 2
password
_000
> OK
> CANCEL
Step 4
password
5_00
> OK
> CANCEL