surge suppression in one of these devices could sacrifice itself after
a catastrophic event. If the telephone, cable or satellite signal will
no longer pass through our protector, please send your M10-HT-
PRO to Panamax for servicing. To test this, simply disconnect the
incoming and out going cable from the M10-HT-PRO. Connect the
incoming connector to the component that formerly received the out
going connector, thus by-passing the in-line protection. If the signal
is present (but not when used with the M10-HT-PRO's) then the
protection circuit is damaged (assuming it worked properly before
the storm or catastrophic event).
Circuit Breaker
If the M10-HT-PRO is connected to an AC outlet where sufficient
voltage is present, the unit should operate properly with the
protection OK indicator lit, after the main power switch is turned
to the on position. If the unit still does not function under these
conditions, check the circuit breaker button. It is the round black
button adjacent to the incoming AC cord. If the circuit breaker trips
immediately, there may be too great of a current load placed upon it.
Simply disconnect one product at a time until this no longer happens.
If the breaker trips with no components connected, there may be a
wiring defect that requires Panamax service.
Indicators
Extreme Voltage Shutdown Indicator
Panamax's SMP+ circuit senses sustained voltages that are high
enough to cause damage to your components, and shuts the
power down before damage can occur. Such conditions can include