UK
PROGRAMMING FLOWCHART
Change
Master Code
1
Enter New
Master Code
Press 6 Digits
Master/Slave
Select Type of Wiegand
selection
2
0
1
2
1
2
Master
Wiegand
Wiegand
Slave
26bit
30bit
Direct Menu
exit
Entering Menu is always done with B + 000000 if the Master Code is not changed.
Submenu 0 - Master/Slave Selection. 1(Master) when the keypad is connected with proximity reader DINMTPX. Default = 2(Slave)
Submenu 1 - Change Master Code. The Master Code must be 6 digits. After enrolling new Master Code the DINPAD-M automatically exits
the Menu and the new master code must be typed to enter the menu.
Submenu 2 - Select Type of Wiegand. With this the Keypad can be adjusted to send 4 different Wiegand Outputs. The Wiegand selected
must be the same as the controller's Wiegand Input where the DINPAD-M Keypad is being connected. Example: If you use a controller that
recognizes Wiegand 34bit, then enter the menu of DINPAD-M, press 2, then press 3.
Submenu 3 - Select Output Protocol. The Keypad can send the Code by different Protocols. Use "Single Wiegand" when connected to third
party controllers. When "Single Wiegand" is selected, what is typed on the Keypad the same will be sent as Wiegand Number. Use Double
Wiegand when connected to EWS, use Clock&Data when connected to controller with Clock&Data input, use Codix when connected to Vi200,
EX5, EX7, INOX99 or VKP99.
Submenu 4 - PIN Code Length. If "0" is selected, then any PIN Code with any length can be sent, but the PIN Code is typed with "A" for
confirmation( ex. 123 + A). If 1 to 8 is selected the PIN Code length is determinated by the number selected.
Submenu 5 - Entry Mode. "Only PIN Code" is disabling the proximity and DINPAD-M+DINMTPX works as keypad only. "Only Card" is
disabling the Keypad and DINPAD-M+DINMTPX works as Proximity Reader. "Card and PIN Code" defines the double security, both the Card
and PIN Code is required for the Wiegand to be sent. "Card or PIN Code" enables normal operation.
Submenu 6 - Presets.
The Presets are set of preprogrammed parameters for easy programming.
6-1 "Wiegand 26bit Normal" -
6-2 "Wiegand 34bit Normal" -
6-3 "Wiegand 34bit EWS Mode" -
6-4 "Wiegand 26bit EWS Mode" -
6-5 "Codix" -
Presets 6-3 and 6-4 to be used always when DINPAD-M is connected to EWS firmware ver.2.42 or higher.
Submenu 7 - Site Code Length. Set the code length sent to Host. Default is "0". To be used only in specific cases.
Submenu 8 - Enter Site Code. Put the site code always in 5 digit format (ex. 00170).
Submenu 9 - Backlight. Turns ON/OFF the backlight.
www.visual-plus.com
Select Output Protocol
3
1
2
3
4
Single
Double
Clock &
Codix
Wiegand
Wiegand
Data
PIN Code Length
4
3
4
0
for any length
Wiegand
Wiegand
with "A"
34bit
40bit
in the end
Type: Wiegand 26bit; Output: Single Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
Type: Wiegand 34bit; Output: Single Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
Type: Wiegand 34bit; Output: Double Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
Type: Wiegand 26bit; Output: Double Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
Output: Codix; PIN Length: any length with "A" in the end; Entry Mode: Card or PIN Code
B + 000000
Enter "Master Code"
Validation OK?
Yes
1 small beep + 1 long beep + Orange LED is 'ON'
Entry Mode
5
1
2
3
4
Card and
Card or
only PIN
only
PIN
PIN
Code
Card
Code
Code
1 - 8
1
2
for lengths
Wiegand
Wiegand
between
26bit
34bit
1 to 8 digits
normal
normal
Press "A" to validate
and exit the menu
(orange LED OFF)
4
No
Error Beep
(3 short beeps)
Site Code Length
7
3
1
2
Site Code
Site Code
No Site
between
between
Code
0 to 255
0 to 15
Presets
6
3
4
5
Wiegand
Wiegand
Codix
34bit
26bit
EWS
EWS
Backlight
9
4
0
1
Site Code
Backlight
Backlight
between
OFF
ON
0 to 65535
Enter Site
Code
8
5 digits
DINPAD-M