11 Specifications
Detection Method
Microwave Frequency
Power Input
Current Draw
Temp Compensation
Alarm Period
Alarm Outputs
Tamper Switch(s)
Warm up Period
LED Indicator
RF Immunity
ElectroStatic Immunity
Transient Immunity
Operation Temp
Dimensions
Weight
European directives
European standards
requirements:
USA & Canada
Protection Degree
Specifications are subject to change without prior notice.
•
FCC COMPLIANCE STATEMENT
FCC ID: F5309LC171
CAUTION: Changes or modifications not expressly approved by Digital
Security Controls could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not
installed and used properly, in strict accordance with the manufacturer's
instructions, may cause interference to radio and television reception. It
has been type tested and found to comply with the limits for Class B
device in accordance with the specifications in Subpart "B" of Part 15 of
FCC Rules, which are designed to provide reasonable protection against
such interference in any residential installation. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause interference to television or radio reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
· Re-orient the receiving antenna
· Relocate the alarm control with respect to the receiver
· Move the alarm control away from the receiver
· Connect the alarm control into a different outlet so that alarm control
and receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced
radio/television technician for additional suggestions. The user may find
the following booklet prepared by the FCC helpful: "How to Identify and
Resolve Radio/Television Interference Problems". This booklet is
available from the U.S. Government Printing Office, Washington, D.C.
20402, Stock # 004-000-00345-4.
INDUSTRY CANADA COMPLIANCE STATEMENT
IC:160A-LC171
The term 'IC:' before the radio certification number only signifies that
Industry Canada technical specifications were met.
This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numérique de la classe B est conforme à la norme
NMB-003 du Canada.
Dual PIR AND MW
24.125 GHz
9.6 to 16Vdc
Active: 24mA (±5%)
Standby: 21mA (±5%)
Yes, Dual slope temperature compensation
2 sec (±0.5sec)
Form C (NC, NO, Common)
28Vdc 0.1 A with 10 Ohm series protection resistor
Two Switches
N.C 28Vdc 0.1 A with 10 Ohm Series protection resistors
Opens when cover is removed from unit's base or if base is removed from
wall
120sec (± 5sec)
LED is ON during ALARM (configurable)
10 V/m plus 80% AM from 80 MHz to 2GHz
6kV contact, 8kV air
1kV
-35ºC ~ +55ºC (-31° F ~ +131° F)
200mm x 86mm x 80mm (7.8" x 3.4" x 3.2")
500gr. (1.1 lb)
RTTE directive:1999/5/EC
EMC directive: 2004/108/EC
Low Voltage directive: 2006/95/EC
RoHS directive: 2002/95/EC
EN300 440-2; EN301 489-1; EN50130-4 +A1 +A2; EN61000-6-3+A11
EN60950-1
EN50131-1 / EN50131-2-4 / EN50130-5
47CFR part 15, subpart C, section 15.245; 47CFR part 15, subpart B
RSS210; ICES-003
IEC 60529: IP 65
RTTE Compliance Statement:
15
EN