Front and Back Panel Descriptions
Unsafe Voltage
Power Switch
Indicator
Press the power
This LED will illumi-
button to turn the
unit ON or OFF.
nate in red to warn
the user that an
unsafe voltage level
is occuring.
BANKS
1
2
3
4
POWER
Outlet Bank 2
Outlet Bank 1
Indicator
Indicator
Illuminated blue
Illuminated blue
when outlet bank 2
when outlet bank 1
is switched on.
is always on.
Outlet Bank 3
Outlet Bank 4
Two switched, high-current outlets controlled by the
Two always on, battery pow-
ered, surge protected outlets
front panel Power Button or the DC Trigger input.
Bank 3 has a 5 second turn on delay and turns off
for connected equipment
immediately. The High Current outlet provides power
ensure temporary uninterrupted
operation of connected equip-
from a low impedance noise filtration circuit that
does not limit the current to your equipment. Its
ment during a power failure.
output is noise isolated from all other outlet banks.
BATTERY
BANK 4
BANK 3
BACKUP
CURRENT
Outlet Bank 2
Four switched outlets with Linear Filtration
Technology (LiFT) controlled by the front panel
Power Button or the DC Trigger input. Bank 2
will turn on immediately and turn off after 5
seconds. Its output is noise isolated from all
other banks.
Meter Dimmer /UPS Test Button
A quick press of the button will cycle the
meter and front panel through several
levels of brightness. Press and hold the
button to initiate an UPS test cycle. During
UPS mode, pressing the button will turn off
the internal warning buzzer.
UNSAFE
WIRING
VOLTAGE
FAULT
O VOLTS IN
EST'D BATTERY: 60 MIN
DISPLAY/
UPS TEST
Outlet Bank 3
Indicator
Illuminated blue
when outlet bank 3
is switched on.
HIGH
BANK 2
SWITCHED
BANK 2
Outlet Bank 1
Two always on outlets with
Linear Filtration Technology
(LiFT). Power will only be
turned off under a fault con-
dition, or when the Power
Button is switched off. Its
output is noise isolated from
all other outlet banks.
Digital Voltmeter/UPS Status Display
During normal operation, the digital LED voltmeter
indicates the incoming line voltage. If line voltage
drops below 90VAC, or exceeds 132VAC, the Unsafe
Voltage LED will flash, and during battery backup
(UPS) mode the display will indicate the estimated
minutes of battery backup time.
Outlet Bank 4
Wiring Fault Indicator
Indicator
This LED will illuminate in red to warn the user that a wiring problem such
Illuminated blue
as a bad/missing ground or reversed wiring exists within the AC receptacle.
when outlet bank 4
If illuminated, disconnect all equipment and contact an electrician to insure
outlet is properly wired.
is on.
Circuit Breakers for
Overload Protection
Resettable circuit
breakers provide optimal
overload protection.
ALWAYS
SWITCHED
BANK 1
ON
AC Power Cord
Voltage Sense Trigger Output
3.5mm (1/8") Mini-Plug jack.
4
IR Control Section
Indicator LED's – Indicates
status IR Output Jacks –
Standard 1/8" (3.5mm)
mono jack for connection to
an IR flasher (IR flashers not
included)
CIRCUIT
BREAKER
UPS
IR OUT __ STATUS _ IR LEARN _____________ IR INPUT _
CIRCUIT
BREAKER
MAIN
LAN IN
LAN OUT
MAIN POWER
IN
120VAC/12A
12V
TRIGGER
Phone Jack
LAN Jack
Protection circuit for one standard
Protection circuit for one
10/100 baseT Ethernet line.
telephone or pay-per-view lines.
Phone circuit is auto-resetting. Incom-
Incoming LAN line MUST be
plugged into the LINE jack.
ing phone cord MUST be plugged
into the LINE jack. Patch cords to the
Patch cord to the equipment
equipment (satellite receiver, digital
MUST be plugged into the
EQUIP jacks. 8 wire protection,
video recorder, telephone, etc.) MUST
be plugged into the EQUIP jacks.
50V clamping.
2-wire protection, 270V clamping.
Removable Battery
Access Panel
Easy to remove for
battery access and
replacement.
MX5102
Universal TV Coaxial Jacks
3 pairs of bidirectional protec-
tion circuits optimized for
satellite, cable, and antenna
TV signal lines.
UNIVERSAL COAX PROTECTION
1
2
3
TEL IN TEL OUT