System Messages - SafeGuard Industrial Aramsco Syclone XL Manuel D'utilisation

Déshumidificateur portatif
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

lasting, protective shine, use an automotive interior
treatment product.
As Needed
Clean Pump Check Valve and Basin. If the unit
displays the message "ER9 PUMP BLOCKED PUMP
& HOSE", the pump check valve and pump basin may
need to be cleaned. This requires removal of the front
housing.
Clean coils. Inspect the horizontal evaporator (cold)
coil with the front cover removed. If excessive dust and
debris is present, vacuum thoroughly and/or clean with
alkaline (non-acidic) coil cleaner.

SYSTEM MESSAGES

The Control Panel will display the following messages
based on system performance and environmental
conditions. User action, if any is required, is indicated
in the third column.
C O N T R O L P A N E L
M E S S A G E
INITIALIZING
FIRMWARE VERSION
XXX
FXXX-XXX
OFF
PLEASE WAIT
COMP. DELAY XX
UNIT ON XXXX HRS
INLET XXX°F / XX%
HUMIDISTAT
INLET XXX°F / XX%
LOW TEMP
INLET XXX°F / XX%
---
PUMP PURGING XX
HI TEMP CYCLE
REMAINING XX MIN
---
DEFROST XXXX
WAIT FOR
DEFROST XXX
WAIT FOR
UNIT DRYING XXX
CHECK FILTER >
OFF
CLEAN COILS >
OFF
07-02353A F588
E X P L A N A T I O N
Unit is powering up.
Indicates control board firmware version number.
Model number.
Unit has finished powering up and is operating.
60s delay before compressor turns on. Allows system
pressure to equalize.
First line: indicates total operating hours.
Second line: Toggles between inlet temperature and
inlet RH every 2 seconds.
First line: indicates unit is in humidistat mode
Second line: Toggles between inlet temperature and
inlet RH every 2 seconds.
Unit shuts off if inlet temp below 45°F/7°C. Turns back
on when inlet reaches 50°F/10°C.
Displays when the Pump Purge button is pressed.
Shows time remaining in seconds.
Unit overload limit reached. Cool-down initiated.
Unit is defrosting, with countdown in seconds.
Unit turned off when coil is cold or already in a defrost
cycle. Proceeds to finish cycle or initiate one to clear the
coils of ice before storage.
Occurs when unit is turned off and coil is not frozen.
Clears the coils of water before storage.
Prompt to check filter.
Prompt to clean coils and interior.
Fig. B: Disassembly for Cleaning
Remove the 4
screws from front
housing, and slide
off to access coils
and pump for
service.
6
U S E R A C T I O N
None
None
None
None
None
None
None
None
None
None
None
None
None
Check filter. Press the > key