MATERIAL SUPPLIED

Hood assembled with motor, lamps and grease filters installed.
• 1 Pre-assembled truss
• Instructions for assembly and use
• 1 electrical cable
• 1 cable clamp
• 1 assembly template
• 6 screws Ø 6x70
• 6 wall plugs Ø 10x60
• 14 screws Ø 4x7
• 14 cage nuts
• 40 screws Ø 3.5x9.5
• 4 screws 3x9
Filter Version only:
• 1 Filter connector with extensions
• 6 screws Ø 3.5x9.5
INSTALLATION - PRELIMINARY ASSEMBLY INSTRUCTIONS
The hood is designed for installation and use in "Extractor version" or in "Filter version".
Note: The model with electric shutter can only be used in "Extractor version" and the exhaust pipe must be connected to a peripheral extraction unit.
Extractor Version
Fumes are extracted and expelled to the outside through an exhaust pipe (not supplied) fixed to the hood exhaust pipe connector.
Depending on the exhaust pipe purchased, provide for suitable fixing to the exhaust pipe connector.
IMPORTANT: If already installed, remove the carbon filter/s.
Filter Version
Air is filtered through the carbon filter/s and recycled into the surrounding environment.
IMPORTANT: check that air recirculation is facilitated.
If the hood does not have a carbon filter/s, order one/them and fit it/them before use.
Install the hood away from very dirty locations, windows, doors and sources of heat.
The hood comes supplied with all the materials required for installation on most walls/ceilings. However, a qualified technician is needed to make sure that the
plugs are suitable for your ceiling.

INSTALLATION DIMENSIONS

Adjacent wall units
centre line
900 mm min (90 cm wide model)
1000 mm min (100 cm wide model)
1200 mm min (120 cm wide model)
65 cm (gas or combi cookers)
50 cm (electric cookers)
Adjacent wall units
hob surface
GB5