MAC TOOLS EM720C Notice D'instructions page 13

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.2.1 DC Voltage
Range
6V
60V
600V
- Input impedance: 10MΩ.
- Overload protection: 600V DC or AC rms.
- Max. input voltage: 600V DC.
NOTE: the minimum measurement of DC voltage and AC voltage is
>=1.
NOTE : When alternating current is detected at either the DC voltage
or the AC voltage shift, the LCD will display « Err ».
5.2.2 AC Voltage
Range
6V
60V
600V
- Input impedance: 10MΩ.
- Overload protection: 600V DC or AC rms.
- Max. input voltage: 600V AC.
- Frequency range: 45Hz~65Hz.
- Response: Average; calibrated to rms sine wave.
5.2.3 AC Current
Range
20A
200A
600A
800.MACTOOLS
Resolution
0.01V
0.1V
1V
Resolution
0.01V
0.1V
1V
Resolution
0.01A
0.1A
1A
Accuracy
± (0.5% of reading + 3 digits)
Accuracy
± (0.8% of reading + 5 digits)
Accuracy
± (2.5% of reading + 8 digits)
± (3.0% of reading + 10 digits)
13

Publicité

Table des Matières
loading

Table des Matières