EN
8.
Technical specifications
General
ZigBee three-phase power meter with data transmission
specifications
Power supply
230 Vac 1.5 W 50/60 Hz
•
Frequency: 2405 MHz to 2480 MHz
•
Compatible with IEEE 802.15.4
Radio
•
Transmission power; +10 dBm ERP (10 mW)
specifications
•
External antenna with SMA-RP connector
•
Radio range 20 m indoors / 50 m outdoors. Note: the distance is indicative and may vary with ambient
conditions (dimensions and material of walls / floor slabs, etc.)
•
ZR-HM3-50-RC: 50 A max
Max current
•
ZR-HM3-100-RC: 100 A max
per phase
•
ZR-HM3-200-RC: 200 A max
•
Bidirectional active power [W]
Measurements
•
Bidirectional energy [Wh]
Connections
Screw terminals (5.08 mm pitch)
•
ZR-HM3-50-RC: max Ø 15 mm
CT internal
•
ZR-HM3-100-RC: max Ø 15 mm
diameter
•
ZR-HM3-200-RC: max Ø 25 mm
Ambient
•
Operating conditions: 0 ÷ +50°C; <80% R.H. n. c.
parameters
•
Storage conditions: -20 ÷ +70°C; <80% R.H. n. c.
Degree of
IP30
protection
Directives 2014/30 EU; 2014/35 EU; 99/5 EEC; 2011/65 EU Reference standards: EN62053-21: Active energy -
Conformity
Class 1 ±1%; EN62053-23: Reactive energy - Class 3 ±3%; ETSI-EN 300 328; ETSI EN301 489; EN61326-1:2013;
EN50581; EN55010; EN55011; EN61010-1
Dimensions
6-module DIN rail housing 105 x 110 x 60 mm
(L x H x D)
9.
Conformity
All models comply with Directives 2014/30/UE (EMC), 2014/35/UE (LVD) e 2014/53/UE (RED). The appliance (or product) is subject to sorted
collection, in compliance with local regulations on waste disposal currently in force. The Astrel Group hereby declares that this product is
in compliance with essential requirements and other pertinent provisions established under Directive 2014/53/UE (RED). The declaration of
conformity can be viewed at www.astrelgroup.com.
10. Safety and disposal
Electrical and electronic equipment requiring sorted collection, in compliance with local regulations on waste disposal currently in force.
Astrel Group reserves the right to change product specifications without notice.
16