Operating manual SIRIS
Undercrawl protection
The SIRIS movement sensors all have undercrawl protection. With a radius of three meters
(270° and 360°) or one meter (120° and 200°), even intruders who approach on all fours can
be detected.
3. INSTALLATION/MOUNTING/CONNECTION
Before mounting, please heed the following points:
•
Before mounting the product, disconnect the mains supply.
•
The minimum height of the sensor is 1.80 m.
•
All range details refer to a mounting height of 2.50 m (deviations cause a change in the
detection area)
•
Optional function (max. range) is achieved if the mounting is sideways to the direction of
movement (Fig. 1).
•
Heed the line of site to the sensor since infrared radiation cannot penetrate fixed objects.
•
In order not to influence the installed light sensor, adhere to a minimum distance of 1 m
to the connected lighting and light sources must not be directed directly at the sensor.
•
Consider local circumstances such as neighbouring land/distance to the street.
•
Only mount the movement sensor on a fixed, even subsurface (wall/ceiling).
The wall socket and sensor must be connected to one another via a plug. For mounting,
disconnect the parts from one another. Use a screwdriver in the side opening (line) and lift in the
direction of the sensor while pulling the wall connection socket from the sensor (Fig. 2.1).
For wall mounting, the cable feeds must point downwards. For ceiling mounting, the cable feeds
must point forwards. Feed the line in and mount the wall socket in the desired mounting
location (Fig. 3.1). For corner mounting, use one of the two corner mounting brackets (Fig. 3.2).
Connect the movement sensor according to the circuit diagram
(Fig. 4).
For ceiling mounting, the two-part sensor must be turned 180° against itself (Fig. 5)
Plug the sensor into the wall socket until it snaps in (Fig. 2.2).
Note: the movement sensor must always be fastened so that the sensor points downwards.
4. COMMISSIONING AND ADJUSTMENT
After successful mounting and switching on of the mains supply, the device carries out a self-test
cycle which lasts approx. 30 sec; this signals that the connected load is switched on. After this
period has elapsed, the device is ready for operation. With detection, the focus LED stays on
permanently. In test mode, the focus LED light up permanently and the load is switched on for
approx. 2 sec.