The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Motor power supply: ............................... 18 V DC
Idling speed: .......................................0-900 min
Clockwise/counter-clockwise: ........................Yes
Weight: .....................................................1.25 kg
Caution!
This tool comes without batteries and without a
charger, and it is allowed to be used only with
lithium-ion batteries of the Kraftixx series!
Lithium-ion batteries of the Kraftixx series are al-
lowed to be charged only with Kraftixx chargers.
Danger!
Sound and vibration
Sound and vibration values were measured in
accordance with EN 60745.
L
sound pressure level ..................... 76.4 dB(A)
pA
K
uncertainty ............................................. 3 dB
pA
L
sound power level ........................ 87.4 dB(A)
WA
K
uncertainty ............................................. 3 dB
WA
Wear ear-muff s.
The impact of noise can cause damage to hea-
ring.
Total vibration values (vector sum of three direc-
tions) determined in accordance with EN 60745.
Impact drilling in concrete
Vibration emission value a
K uncertainty = 1.5 m/s
The specifi ed vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equip-
ment is used and may exceed the specifi ed value
in exceptional circumstances.
Anl_KX_BH_18_Li_SPK13.indb 16
Anl_KX_BH_18_Li_SPK13.indb 16
-1
= 10.07 m/s
2
h
2
- 16 -
GB
The specifi ed vibration value can be used to
compare the equipment with other electric power
tools.
The specifi ed vibration value can be used for initi-
al assessment of a harmful eff ect.
Keep the noise emissions and vibrations to a
minimum.
•
Only use appliances which are in perfect wor-
king order.
•
Service and clean the appliance regularly.
•
Adapt your working style to suit the appliance.
•
Do not overload the appliance.
•
Have the appliance serviced whenever ne-
cessary.
•
Switch the appliance off when it is not in use.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.
Danger!
The electric power tool generates an electro-
magnetic fi eld during operation. Under certain
circumstances this fi eld may actively or passively
impede medical implants. To reduce the risk of
serious or fatal injuries, we recommend persons
with medical implants to consult their doctor and
the manufacturer of the medical implant prior to
using the equipment.
5. Before using the equipment
Be sure to read the following information before
you put the cordless impact drill into operation:
1. Charge the battery pack only with a charger
from the Power-X-Change series.
2. Only ever use sharp drill bits and screwdriver
bits which are suitable for the purpose and in
faultless condition.
24.01.2022 13:20:47
24.01.2022 13:20:47