Product Sheet - Tectro TBH 570-2 Manuel D'utilisation

Masquer les pouces Voir aussi pour TBH 570-2:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 68
Display shows
The flue blower is defec-
"Alar fan fail"
tive or the printed circuit
board cannot measure its
speed.

9. PRODUCT SHEET

Supplier's name or trademark
Model
Energy efficiency class
Type of stove
Direct heat output (*)
Indirect heat output (*)
Energy efficiency index
Power consumption (ignition/normal operation)
Power supply
Usefull energy efficiency at nominal output / reduced output (*)
Other precautions related to assembly, installation or mainte-
nance of local space heating
CO level at 13% O
2
Flue gas mass flow nom. power
Flue gas mass flow red. power
Average dust content at 13% O
For rooms up to**
Flue diameter
Flue gas temperature at nominal/reduced capacity
Required chimney draught
Required flue choke valve
Can be used on a chimney combination with flue
Type of fuel (****)
Nominal length/diameter of fuel
Pallet hopper volume
Autonomy (min-max)
Main air vent
Recirculation blower
Air filter
Net weight
(*) Meets EN 14785
(**) only indicative, varies per country/region
(***) To be determined by authorised professional fitter
Either the flue blower, the printed circuit
board or the speed sensor is defective, or
the wiring is damaged or loose. Fix the de-
fect. Only to be done by a Tectro-approved
technician
nominal/reduced capacity (*)
2
Tectro
TBH 570-2
A+
Wooden pellets
kW
7.48
kW
0.0
122
W
300 / 100
V/Hz
230/~50
%
91 / 92.7
Consult manual
%
0.01 / 0.04
g/s
6.3
g/s
3.4
mg/Nm³
21.3
170
mm
80
°C
128
Pa
11
Possible***
No
Ø 6 mm
Din+/Önorm+/
EN+
mm
30 / 06
kg
13
h
8 - 22
Yes
Yes
No
kg
77
4
163

Publicité

Table des Matières
loading

Table des Matières