TROUBLESHOOTING
Problem
Display shows "
"
Display shows "
"
Heater does not blow
warm air.
Temperature display not
matching room
temperature read by other
thermostats.
The heater is taking a long
time to reach desired room
temperature.
Temperature will not
change.
Heater does not turn on
but other functions work
fine.
Unit continues to run after
reaching set temperature/
or powering off.
Heat turns on randomly.
Buttons do not work.
Control panel does not
illuminate.
How many quartz heating
elements are in my unit?
A3481
Root Cause
Corrective Action
The thermostat sensor is
Unplug the heater, remove the back panel of the heater and check that the ther-
broken or disconnected.
mostat is plugged into the main circuit board. If this does not solve the problem
contact customer service.
The thermostat sensor is
Contact customer service.
broken.
Normal operation, will continue to run for several minutes before shutting down.
Cool down cycle
Times will vary based on temperatures. During this time cool air will blow.
Perform a master reset; turn off and unplug unit. Hold down main power but-
ton on the unit itself. Continue to hold button down while plugging unit back
Not reaching set
in. Once unit is plugged back in continue to hold button for 5 seconds and then
temperature.
release. Turn unit back on and temperature should flash 72 degrees then display
the ambient room temperature.
Not reaching set
Unit is designed to be used as a supplemental heat source in conjunction with a
temperature.
primary heat source.
Press and hold timer button, 00 flashes then a single digit between -9 degrees to 9
degrees will appear. At this point release the timer button and use the arrow up/
Calibration
down button to adjust the temperature variance up to 9 degrees +/- . After 10
second without control input the heater will exit thermostat calibration.
Unit is designed to be used as a supplemental heat source in conjunction with a
Improper use of unit
primary heat source.
Your unit should always be positioned on an inside wall with proper insulation.
Location
The heater provides supplemental heating for up to 1000 sq/ft in conjunction with
a primary heat source.
The back and side of the heater should be greater than 6 inches away from objects
Location
for proper air intake.
Use of surge protector/
Plug unit directly into the wall outlet.
extension cord.
Defective control panel
Replace control panel circuit board.
circuit board.
Turn the POWER to "OFF" and unplug the unit from the wall outlet for 5
Manual reset needed
minutes. After 5 minutes plug the unit back into wall outlet, and operate as
normal. If the problem persist contact customer service.
Normal operation, will continue to run for several minutes before shutting down.
Cool down cycle
Times will vary based on heating. UNIT WILL BLOW COOL AIR.
Ambient room
Normal operation, unit will periodically run to test air temperature.
temperature scan.
Will run 3 minute of cool air and 3 minutes of warm air.
Defective control panel
Replace control panel circuit board.
circuit board.
Defective control panel
Replace control panel circuit board.
circuit board.
Product Inquiry.
4 Infrared Quartz heating elements.
7
www.tsicustomerservice.com