REMOTE CONTROL
1.- q: button to enter or exit Standby mode.
2.- INPUTS: input channels 1-4.
3.- OUTPUTS: output channels 1-4.
4.- ENTER: confirm the operation. This button must be pressed when
performing an operation with the remote control for the changes to
be set. For more information see the OPERATION section.
5.- ALL: allows you to select all inputs/outputs. For more information
see the OPERATION section.
6.- EDID: allows the selected input(s) to copy the EDID information
from the desired output. For more information see the OPERATION
section.
7.- CLEAR: allows you to cancel the operation that is currently being
performed. For more information see the OPERATION section.
OPERATION
SENDING INPUTS TO OUTPUTS
- To send an input to an output or several outputs, press the corresponding input button, then press the
output(s) and, finally, ENTER to save.
Example 1, input 1 to output 4: INPUT 1 + OUTPUT 4 + ENTER
Example 2, input 2 to output 3 and 4: INPUT 2 + OUTPUT 3 + OUTPUT 4 + ENTER
- Send an input to all outputs.
Example, input 2 to all outputs: INPUT 2 + ALL + ENTER
CANCEL CURRENT OPERATION
- When you want to cancel an operation you are performing with the remote control, press the CLEAR
button and the matrix will return to the previous configuration status.
EDID MANAGEMENT
Function available on the remote control.
- To copy the EDID from an output to an input you must press the EDID button followed by the input and
output, and finally, press ENTER to save. An input (input 2) copies EDID information from an output (output 4):
Example, copy EDID from output 4 to input 2: EDID + INPUT 2 + OUTPUT 4 + ENTER
- To copy the EDID from one output to all inputs you must press the EDID button, followed by ALL (referring
to all inputs). Next, the output from which you want to copy the configuration and ENTER to save.
Example, copy EDID from output 4 to all the inputs: EDID + ALL + OUTPUT 4 + ENTER
- 3 -