1• • • • Wiring diagram :
JUMPER
Non fitted : Buzzer deactivated
Fitted : Buzzer activatd
2• • • • Recommended cables:
Use a multi-conductor cable, pair shielded. When power is
supplied with the same cable we recommend:
1 pair AWG24 for up to 30 m
2 pairs AWG24 for up to 60 m
3 pairs AWG24 for up to 100 m
3• • • • Buzzer
The buzzer gives an indication of correct read, not depending
on the eventual authorizations or access rights given to a card.
It will emit a brief sound as soon as a card or tag is read. It is
possible to shut it off by removing the jumper located just
nearby the buzzer.
4• • • • Led
The led is bicolor (red & green). When the reader is powered
on, it is amber (red+green). It can be driven by the remote
system to light it either red or green, by bringing a 0V
respectively on the red or green inputs of the reader's
connector.
5• • • • « Mode » input
By default, when this input is not connected, the reader will
automatically delay the transmission of the code every 2
seconds when a card is left in the reading field. If a new card is
shown to the reader before this time laps, its code will be
transmitted immediately.
If you want to activate or deactivate the delay:
1. Power off the reader.
2. Connect the input Mode to 0V to deactivate the delay.
Do not connect the input mode to activate the delay.
3. Power on the reader.
⇒ Check if the reader is operating properly by presenting a
card. The reader should then beep quickly on each reading.
Proximity reader - Model LXS R21 (Wiegand and Clock & Data)
Power
12V / 0,5A min.
0 1
2 3 4 5 6
7
1 pair AWG35 for up to 50 m
2 pairs AWG35 for up to 100 m
© STId 2009 – NI017A04 - Ed. 21/09/2009
Installation procedure
LEDS commands
Data signals
R21 series
(ISO 2x)
0
0V
1
+12 VDC
2
Code
3
Data
4
Clock
5
Mode / Scan
6
Red Led
7
Green Led
5• • • • « Scan » input – 2L protocol only
This input allows deactivating the RF field which stops card
detections. To deactivate the RF field connect the input "Scan"
to 0V.
6• • • • Installation
e)
Connect the reader
f)
Test the reading and communication.
g)
Attach the reader on the wall, or on standard electrical
flush-boxes. Install the screw caps.
Caution: Screw caps are made to be hard to remove
once installed. We recommend making all the tests
before installing them.
7• • • • Precautions for installation
Power supply tension at the reader's connector should be
strictly comprised between 10.5V and 15V.
Keep the reader away from computer or power cables as
much as possible. They can generate an electrical
perturbation that is function of their proximity and
radiation level.
Distance to respect between two readers : parallel plan :
30 cm – Same plan : 40 cm – Perpendicular : 25 cm.
If the reader is mounted on a metallic surface it can affect
the reading distance. To get the maximum reading
distance, the reader should be installed at no less than 7
cm from any metallic surface.
R21 series
(ISO 3C)
0V
+12 VDC
Code
Data
Clock
Mode
Red Led
Green Led