Installation
Using the short hose as an extension
22
English
DV7700K-03170U-01_EN (US).indd 22
B
A
C
1. Close the cold water tap. If you have
a washer cold water hose attached to
the cold water faucet, unscrew and
remove the hose. Then, connect the
short hose (B) to the cold water tap.
Turn the coupling manually until it is
tight.
2. Using pliers, tighten the coupling an
additional two-thirds turn. Do not
overtighten because the coupling may
be damaged.
3. Connect the Y connector (A) to the brass
male end of the short hose. Turn the
coupling manually until it is tight.
4. Using pliers, tighten the coupling an
additional two-thirds turn. Do not
overtighten because the coupling may
be damaged.
5. Connect the angled end of the water
hoses (C) to the filling valve at the
bottom of the rear frame. Turn the
coupling manually until it is tight.
6. Using pliers, tighten the coupling an
additional two-thirds turn. Do not
overtighten because the coupling may
be damaged.
7. If you detached the cold water hose
from your washer, attach the hose to
the free end of the Y connector, tighten
the coupling until it is tight, and then,
using a pliers, tighten an additional
two-thirds turn.
8. Open the cold water tap, and then check
for any leaks.
2015-12-08
1:05:22