Télécharger Imprimer la page
Crow MAG2 Manuel D'utilisation
Crow MAG2 Manuel D'utilisation

Crow MAG2 Manuel D'utilisation

Contact d'ouverture avec entrée universelle sans fil

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

1
SH-MAG2 - 8F/9F
FREEWAVE2™ TWO WAY WIRELESS
MAGNETIC DOOR/WINDOW CONTACT
INSTALLATION INSTRUCTIONS
P/N 7105689_B
4
OPERATION
The Wireless Magnetic detector transmits the
following events data:
SUPERVISION - a periodical transmission every 7
min. by default, indicates detector's presence.
ALARM - Alarm transmission triggered by
intrusion detection by REED SWITCH and WIRE
input.
(Selectable, see section 18)
LOW BAT – Whenever the battery reaches a pre-
set low level (~2.9V) Battery Low signal will be
sent with the next scheduled message
(Supervisor, Alarm, etc.).
TAMPER – Whenever the SH-MAG2 cover is
removed or tore off wall, a message will be
transmitted with "Tamper" signal.
7
Fig. 3 - CIRCUIT LAYOUT
10
SELECT MOUNTING LOCATION
It is recommended to mount the SH-MAG2
vertically on a flat area to get maximum range.
As the detector is a wireless transceiver, and in
order to take full advantage of its sophisticated
operation, do not install the detector in areas where
large metal objects could interfere with the
transmission of signals.
It is recommended to attach transmitter to the
fixed frame and the magnet to the moveable part
(door or window), as shown on section 14.
Installation is not allowed on a ferromagnetic
surface.
For detector installation it is
recommended to use
SCREW 3x30 PH. FLAT HEAD
CAUTION: using a different or a
bigger screw can damage the
electronic board.
2
INTRODUCTION
The SH-MAG2 is an advanced magnetic contact
sensor with integrated RF transceiver designed to
be a fully supervised low-current device
The SH-MAG2 is a part of the FREEWAVE2™
which is a supreme wireless line of devices that
uses an advanced 2way RF transceiver combined
with an intelligent communication protocol.
A built-in reed switch and/or an external wired input
may be applied in this device.
To maximize security, an 200k end-of-line resistor is
monitored on the external wired input.
SH-MAG2 uses smart message control, which
verifies
that
all
messages
are
transmitted, so that no intrusion event will be
uninformed to the system.
Each SH-MAG2 has a unique factory set ID code
(24bit) which by registration is set into memory of
the paired Shepherd system enabling more secured
communication
and devices
to
be
controlled from a specific RF transceiver.
5
FIG. 1 - REMOVAL OF FRONT COVER
8
MAGNET LOCATION
11
RSSI – RF SIGNAL INDICATION
The shepherd control panel has "RF Signal
Strength Indication" (RSSI) for each
transceiver in order to help the installer to
define the best location for the detector from
RF perspective.
RSSI level display
1.
Enter to installer programming via installer
webpage
2.
Option 1: go to zones level
3.
Option 2: go to Overview level
4.
Option 3: Mobile App.
FEATURES
 State-of-the-art 2-way wireless security system
 Freewave2 advanced & secured RF protocol
GFSK with 5 frequencies & LBT
 Low current Technology
 Powered by a single 3V Lithium battery
 Battery life: more than 5 years
 Available Frequencies: 868MHz / 916MHz
 Contact Open/Close transmission
 Tamper Open/Close transmission
 Supervision transmission
 Battery status send on every transmission
successfully
 LED indications for monitoring
 Range up to 500m on open space.
 Unique ID number
 Front and back tamper.
 Alarm trigger either by the internal reed switch
and / or by wired terminal
remotely
 Wired terminal with E.O.L 200K resistor.
FIG. 2 - BATTERY PLACEMENT
LEARNING PROCESS
For pairing process, please refer to your control
panel instructions.
To pair your device with Shepherd™ panel, please
proceed as follows:
1. Enter in installing mode via the "Installer Webpage"
2. Go to "Zones" and select the zone # you want to
learn
1. Add Zone - (Reminder: insert Link Type "ISM",
device's ID, Device Type "Magnetic Contact".)
2. Set the detector configuration: supervision time,
internal switch...and etc, and save configuration.
3. Place a battery as instructed in Figure 2 and wait
until the Red / Green LED stops blinking.
4. The device should register to the Control Panel.
5. When
registration
completed, the Green LED will constantly light ON
for 3 seconds and then turn OFF.
6. If Green LED continues flashing more than 5
minutes and stopped, please check SH-MAG2
settings details, remove battery and repeat steps
3,4,5.
FIG. 4 - KNOCKOUT HOLES
3
6
9
process
is
successfully
12

Publicité

loading

Sommaire des Matières pour Crow MAG2

  • Page 1  Range up to 500m on open space. uninformed to the system.  Unique ID number Each SH-MAG2 has a unique factory set ID code  Front and back tamper. (24bit) which by registration is set into memory of  Alarm trigger either by the internal reed switch...
  • Page 2 This Warranty Certificate is given in favor of the purchaser (hereunder the "Purchaser") purchasing the products directly from Crow or from its authorized distributor. Crow warrants these products to be free from defects in materials and workmanship under normal use and service for a period of 12 months from the last day of the week and year whose numbers are printed on the printed circuit board inside these products (hereunder the "Warranty Period").
  • Page 3 1. Entrez en mode d'installation via la "page Web de l'installateur". 2. Allez dans "Zones" et sélectionnez le numéro de la zone que vous souhaitez attribuer au MAG2. 3. Ajoutez une zone - (Rappel : entrez le type de lien "ISM", le numéro de série de l'appareil...
  • Page 4 Montez l'aimant près du marquage. Placez la pile CR123A en respectant la bonne Installation de base à 10mm entre le MAG2 et l'aimant. polarité Zone n° X Ouvrir Placez le couvercle en le remettant dans la goupille...