InStALLAtIOn & OPERAtIOn
InStALLAtIOn
Proper care, maintenance and lubrication ensures longevity. The com-
pressor should always be level for proper lubrication. Use only in a clean,
dry, and well-ventilated area. The compressor has heat dissipation fins
for proper cooling. Keep the fins and other parts that collect dust clean.
Do not place rags or other materials on top of the compressor, as this
obstructs cooling and can be a fire hazard.
bEfORE OPERAtInG thE AIR COMPRESSOR
PLEASE ChECk thE fOLLOwInG CAREfuLLy:
1)
Check to see that nuts and bolts are all snug.
2)
Check if the quantity and quality of oil is correct.
)
If the intake filters are dirty, they should be replaced or cleaned.
COMPRESSOR LubRICAtIOn
ALwAyS ChECk thE OIL LEvEL AnD
QuALIty bEfORE StARt–uP. DO
nOt ADD OR ChAnGE OIL whILE
thE unIt IS RunnInG.uSE OnLy
RECOMMEnDED nOn-DEtERGEnt OIL.
Compressor oil:
Compressor oil:
* Compressor originally filled with SAE 20W oil (ISO 68)
Compressor oil is a non-detergent mineral oil formulated with additives to
help minimize carbon build-up, increase ring life and reduce oil consump-
tion, for use at ambient temperatures of 0° to 30°C (32°F - 86°F).
RECOMMEnDED OIL.
#EAOIL 10 (1 Litre)
#EAOIL 40 (4 Litres).