5 Technical data
Technical data - electrical ratings
Voltage supply
Power
consumption
Display
Number of digits
Digit height
Display range
Display refresh
A/D transformer
Analog input
Programmable
Parameters
Data memory
Standard
DIN EN 61010-1
Emitted interference
Interference immunity
www.baumer.com
21...53 VAC (50/60 Hz) or
10.5...70 VDC
85...265 VAC (50/60 Hz) or
100...300 VDC
1.8 W
LED, 7-segment display (with 60 unit
stickers for front)
4-digits
10 mm
-1999...9999 („OuE" to signal overflow)
250 ms
Principle ∑∆
Resolution 16 bit
Measuring rate 25/s
Measuring accuracy:
Pt100 1° ±(0.2 % +1-digit)
Pt100 0.1° ±(0.2 % +4-digit)
Temp. coeffic. 100 ppm/°C
Thermocouple ±(0.4 % +2-digit)
Temperature: Pt100,
Thermocouples J,K,T
Measuring range
Resolution 0.1 or 1 °C/°F
Measuring unit °C/°F
>10 years in EEPROM
Protection class II
Overvoltage category II
Pollution degree 2
DIN EN 61000-6-3
DIN EN 61000-6-2