Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Part number
The vinyl siding vent kit allows the owner to extend the vent cap away from vinyl siding. The vinyl siding vent cap extension protects vinyl
siding from possible warpage or discoloration.
new installation
1.
Measure existing wall depth plus 3" for vinyl siding vent cap extension. EXAMPLE: 6" wall depth plus 3" vinyl siding vent cap exten-
sion, total depth is 9".
ATTENTION: When using the DV-822 vinyl siding vent kit, do not exceed the maximum depth of:
10" for Model Number DVC-35(SPP/IP) (7" wall plus 3" depth for DV-822)
13" for Model Number DV-210-(7,9)SG/215-(7,9)SG, DV-25-(1,2)SG, DV-35-(1,2)SG, DVC-55(SPP/IP) (10" wall plus 3" depth for DV-822)
2.
Install furnace according to Installation Instructions and Owner's Manual.
3.
After cutting hole through outside wall, attach vinyl siding vent cap extension to outside wall.
4.
Attach vent tubes, outside mounting plate, and vent cap according to Installation Instructions and Owner's Manual.
5.
Installation is complete.
existing installation
1.
Remove vent cap and outside mounting plate.
2.
Measure existing wall depth plus 3" for vinyl siding vent cap extension. EXAMPLE: 6" wall depth plus 3" vinyl siding vent cap exten-
sion, total depth is 9".
ATTENTION: When using the DV-822 vinyl siding vent kit, do not exceed the maximum depth of:
10" for Model Number DVC-35(SPP/IP) (7" wall plus 3" depth for DV-822)
13" for Model Number DV-210-(7,9)SG/215-(7,9)SG, DV-25-(1,2)SG, DV-35-(1,2)SG, DVC-55(SPP/IP) (10" wall plus 3" depth for DV-822)
3. If wall depth allows the use of the vinyl siding vent cap extension, please order a new flue tube and air tube. The existing tubes will
be too short with the addition of the vinyl siding vent cap extension.
waRning: Do not attempt to add sections of pipe to the flue tube and air tube. An air tight seal is required for both tubes. Only use Empire
Comfort Systems, Inc. flue tube and air tube.
4. With a new flue tube and air tube, remove existing tubes.
5.
Attach vinyl siding vent cap extension to outside wall.
6.
Attach vent tubes, outside mounting plate, and vent cap according
to Installation Instructions and Owner's Manual.
7.
Installation is complete.
Part number
TH-109
TH-107
DV-524
DV-548
DV-870
DV-871
Page 1
installation instRUCtions
DV-822 VinYl siDing Vent Kits
Vent Kits PaRts list
DV-819
R-1595
Description
3" Flue Tube DV-210/215
5" Air Tube DV-210/215
4" Flue Tube DV-25/35/DVC-55
6" Air Tube DV-25/35/DVC-55
4" Flue Tube DVC-35
6" Air Tube DVC-35
Empire Comfort Systems Inc. • Belleville, Il.
Description
Vent Cap Extension (Aluminized Steel/Aluminum Paint)
Screws (8 Required) - #10 x 1-1/2 inch
Vent Kit Instructions
R1595-1-0519

Publicité

loading

Sommaire des Matières pour Empire Comfort Systems DV-819

  • Page 1 TH-109 3" Flue Tube DV-210/215 TH-107 5" Air Tube DV-210/215 DV-524 4" Flue Tube DV-25/35/DVC-55 DV-548 6" Air Tube DV-25/35/DVC-55 DV-870 4" Flue Tube DVC-35 DV-871 6" Air Tube DVC-35 Page 1 Empire Comfort Systems Inc. • Belleville, Il. R1595-1-0519...
  • Page 2 AVERTISSEMENT: N’essayer pas d’ajouter des sections de tuyaux , au tuyau d’échappement et au tuyau d’air. Un joint étanche est exigé pour les deux tuyaux. Utiliser seulement les tuyaux d’échappement et d’air d’Empire Comfort Systems, Inc. Avec un nouveau tuyau d’échappement et un nouveau tuyau d’air, enlever les tuyaux existants.