In which U is the voltage drop in volts (V) and I is the current through the
wire in amperes (A).
���� = 50 × 2.96����Ω = 148�������� for the full 50A charging current.
The voltage drop will then be:
4.14. Three (3) output versions
The three output version chargers have an integrated FET battery isolator
and therefore feature three isolated outputs
Although all outputs can supply the full rated output current, the combined
output current of all outputs is limited to the full rated output current.
By using the three-output version charger it is possible to charge three
separate batteries with only a single charger while keeping the batteries
isolated from each other.
The outputs are not regulated individually. One charge algorithm is applied
to all outputs.
5. Charging algorithms

5.1. Battery selection

The charge algorithm of the charger must fit the battery type connected to the
charger. The following table shows the three predefined battery types available.
A custom battery type can be programmed by the user.
Charging voltages at room temperature:
MODE
NORMAL
HIGH
LI-ION
For 24V battery chargers: multiply all values by 2.
ABS
FLOAT
STORAGE
V
V
V
14.4
13.8
13.2
14.7
13.8
13.2
14.2
13.5
13.5
9
RECONDITION
Max V@% of
Inom
16.2@8%, 1h
max
16.5@8%, 1h
max
N/A

Publicité