rDNet CONNECTION
The system is equipped with an RDNet connection on board.
Using an RDNet controller unit it is possible to:
-
receive status information from the system (amplifiers status, signal levels, system
settings,...).
-
Send commands to the system (mute, solo, change sensitivity, change setting, set user
eq, ...).
-
See the RDNet user manual for details.
rDNet BY-PASS SWITCH
When the RDNet is present and the RDNet LINK LED is green the controller takes control
over the module independently of the BY-PASS SWITCH position.
When the rDNet is not present, the BY-PASS switch act as follow:
-
BY-PASS SWITCH pressed (LED ON): the system bypass the input board and reads
the RDNet user settings (last configuration saved).
-
BY-PASS SWITCH released (LED OFF): the system reads the input board and bypass
the user setting eventually loaded ion the speaker (last configuration eventually saved).
TTS56-A DEfAULT CONfIGUrATION
The TTS56-A factory default configuration (the configuration that the system reads if
the BY-PASS switch is pressed) is the following:
Sensitivity
+4 dBu
High pass
30 Hz
Low pass
90 Hz
Cardioid
OFF
Delay
0
Bypass
OFF
User filters
ALL FLAT
If the user set with RDNet a new configuration, the new configuration will be recalled
when the BY-PASS switch is pressed.
BY-PASS SWITCH
rDNet
ON
ON
OFF
ON
ON
OFF
OFF
OFF
10
BY-PASS LED
fUNCTION
ON
Reads RDNet settings
OFF
Reads RDNet settings
ON
Reads last saved used configuration
OFF
Reads input panel
rDNet
rDNet CONNECTION
rDNet BY-PASS SWITCH
TTS56-A
DEfAULT CONfIGUrATION