Télécharger Imprimer la page
HIKVISION Pyronix KX15DT Mode D'emploi
HIKVISION Pyronix KX15DT Mode D'emploi

HIKVISION Pyronix KX15DT Mode D'emploi

Publicité

Liens rapides

KX15DT
15m Dual-Technology Detector
EN50131-2-2:2008
Security Grade (SG) 2
EN50131-1:2006+A1:2009
Environmental Class (EC) II
PD6662:2010
E N G L I S H
(Diagram references)
1
Disassembling the KX
2
The Printed Circuit Board (PCB)
E
Alarm LED
A
F
Terminals
Resistor Headers (Tamper / Alarm)
B
G
Mains Frequency
Pyro Sensor (DO NOT TOUCH)
C
Sensitivity (Auto/High) - see section.6
H
Microwave Potentiometer (adjust)
D
'AND/OR' Mode- see section.7
3 3
3 4
Cable Entry / Mounting
Bracket Mounting Options
3 5
Installation Hints:
Do not partially or completely obscure the detector's eld of view with
large objects such as furniture.
Avoiding False Alarms:
When the detector is rst powered up, it will run through a
self-test routine, indicated by the ashing LEDs. Once this has extinguished - the detector
is ready to use.
1: Avoid Placing the detector in direct sunlight. 2: Do not let pets and other animals
wander freely whilst the alarm system is armed.
3: Do not mount the detector near heaters or radiators.
4: Do not mount the detector near open windows or air vents.
3 6
A
B
Sensitivity Settings:
Auto Sensitivity (Default)
High Sensitivity
3 7 3 7
AND/OR Mode: "AND" -
Conventional Dual-Tech (both technologies need to be
triggered simulataneously to generate an alarm)
"OR" -
If either single technology detects an intruder activity an alarm will be generated.
3 7 3 8
Microwave Potentiometer: -
Minimum Range (0m), Maximum Range (15m)
Note:
Turning the pot fully anti-clockwise turns o the microwave.
3 7 3 9
EOL Resistor Headers:
The KX15DQ has 2 sets of header pins (as shown). These headers
are used to select the End of Line resistance for EOL wiring applications.
NOTE: If EOL wiring is not used, leave the headers OFF.
3 10
A
N/C - Normally Closed Wiring
(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)
B
Single End of Line Wiring
(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)
C
DEOL Wiring
(EXAMPLE ONLY, SEE CONTROL PANEL INSTRUCTIONS)
D
2x Double End of Line Detectors to One Input
(SEE CONTROL PANEL INSTRUCTIONS)
E
Zone Doubling Example
11
3
Powering Up: When the detector is rst powered up, it will run through a self-test
routine (indicated by the ashing blue LED). Once the LED goes out the detector
is ready to use.
12
3
13
3
The 15m Volumetric Lens.
Dimensions and Weight
Note:
In an EN50131-1 (and INCERT) system the
maximum detection is 13m.
Technical Specification
Model: KX15DT Colour: White LED Colours: Orange (Microwave), Blue (Alarm), Green (PIR)
Casing: 3mm ABS, 0.4mm HDPE in lens area
Detection Method: Low noise dual element pyroelectric sensor & Microwave doppler sensor
PIR Sensitivity: Auto (Default), High
Temperature Compensation: Digital
Detection Range: 15m (13m by EN50131-2-2 & INCERT criteria) Detection Speed: 0.3 - 3.0 m/s
Operating Voltage: 9 - 16V DC 13.8V DC typical
Current Consumption: 24mA @ 12V (Min), 30mA @12V (Max)
Relay Output: 50mA 60V DC, 42 VAC (RMS)
Contact Resistance: < 10 Ω Mounting
Height: 1.8m - 3m (best place 2.4 m)
Tamper Switch: 12V 50mA Temperature:
-40
o
C to 80
o
C (storage) -10
o
C to 40
o
C (certified) -30
o
C to 70
o
C (nominal) Accessories: Wall
and Ceiling brackets
Emissions: EN55022 Class B Immunity: EN50130-4
Proctection against EMI and RF
Compatible with Curtain Lens (Not Included) KX18LC, 15 m and 5 ° coverage
Warranty & Compliance
This product is sold subject to our standard warranty conditions and is warranted against defects
in workmanship for a period of ve years. For further warranty information visit:
www.pyronix.com/warranty
The declaration of conformity and further compliance documentation may be consulted at:
www.pyronix.com/product-compliance.php
Contact Information
For electrical products sold within the European Community. At the end of the electrical products
life, it should not be disposed of with household waste. Please recycle where facilities exist. Check
with your Local Authority or retailer for recycling advice in your country. This product is
approved for use in the Residential, Commercial and Light Industrial Environments.
Secure Holdings, Pyronix Ltd,
Website: www.pyronix.com
Braithwell Way, Hellaby,
Rotherham, South Yorkshire
S66 8QY
UK
 0845 6434 999 (UK). +44(0)1709 535 225
1
START
Lens
Lens
Holder
3
4
A
B
 customer.support@pyronix.com
 www.pyronix.com
PCB
2
PCB
Lens
Illuminator
LED ON
f ) Back
PCB
Tamper
Nut
Screw
Casing Screw
C
6
5
A
C
D
Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
(Default)
= 50Hz
TAMPER
E
= 60Hz
B
LED OFF
D
F
7
AND
OR
Conventional Dual Tech (Both
technologies need to be triggered
simultaneously to generate an alarm)
DO NOT USE 'OR' MODE
WITH THIS PET IMMUNE
DETECTOR
C3
A
A
H
PIR
G
8
Minimum
Range (0m)
Maximum
Range (10m)
Not
D
Recommended
The
®
Note: turning the pot fully anti-clockwise
turns o the microwave
EOL
B
C
RINS549-14

Publicité

loading

Sommaire des Matières pour HIKVISION Pyronix KX15DT

  • Page 1 START KX15DT (Default) = 50Hz TAMPER 15m Dual-Technology Detector Lens = 60Hz Illuminator EN50131-2-2:2008 Security Grade (SG) 2 EN50131-1:2006+A1:2009 Environmental Class (EC) II PD6662:2010 LED ON LED OFF E N G L I S H (Diagram references) Disassembling the KX The Printed Circuit Board (PCB) Alarm LED f ) Back...
  • Page 2 ALARM: TAMPER: 6K8, 5K6, 5K6, 4K7, 4K7, 2K2, EURO GENERIC CONTROL PANEL DEOL DEOL Z1 COM Z2 EOL INPUT 1 EOL INPUT 1 PCX / EURO +12V 0V +12V 0V EOL INPUT 1 +12V 0V +12V 0V TAMPER TAMPER TAMPER ALARM ALARM ALARM...
  • Page 3 KX15DT KX15DT KX15DT KX15DT Tier-immuner Dual-Technologie-Digital-PIR-Melder (15 m) Digitale PIR-detector met dubbele technologie, 15 m Détecteur PIR à double technologie, portée 15 m Rilevatore PIR digitale a doppia tecnologia 15 m EN50131-2-2:2008 Sicherheitsstufe (SG) 2 EN50131-2-2:2008 EN50131-2-2:2008 EN50131-2-2:2008 Beveiligingsniveau 2 Classe de sécurité...
  • Page 4 KX15DT KX15DT KX15DT KX15DT Detector PIR digital con tecnología dual, 15 m Detetor PIR digital de dupla tecnologia de 15 m Dualny cyfrowy czujnik 15 m PIR EN50131-2-2:2008 EN50131-2-2:2008 EN50131-2-2:2008 Certificado Grado 2 Grau de segurança 2 Класс безопасности (SG) 2 EN50131-2-2:2008 Stopień...