Frico Pur825 Manuel D'utilisation page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CE
@
VDE Testmg and Certification
Measurement
Ultraviolet
radiation
ranges from the lower region of visible light (400 nm) to the upper region of X-rays
(10 nm). UV-C is the part of ultraviolet
UV-C light sources emit electromagnetic radiation of 185 and/or 254 nm and can have a germ-reducing
effect. At 185 nm the light induces ozone production. Ozone itself has germ-reducing effects but might
also lead to negative consequences such as irritation or carcinogenic
which
emit
wavelengths under 200 nm will be evaluated with
The time for a defined reduction of germs is evaluated by using the required UV-C dose for a certain
reduction effect and the actual radiation dose of
radiometer between 200 and 270 nm.
Different germs show different sensilivilies towards UV-C radiance. Therefore, the values for the
minimum operating
lime
of the product are shown in tables with the most common
Measurement conditions
•c
Ambient
temperature:
25
Relative
humidity:
60 %
The products under test are supplied by an external power supply according to the voltage and frequency
given on the marking
plate.
The values for the minimum operalion lime of the UV-C air purifier are evaluated assuming a leakproof
room.
Rated voltage
Total power of the
germicidal
Number of lamps
Type of lamp / Type of lamp socket
Lamp life cycle (rated value)
UV-C-Peak
Flow
rate
Dimensions
Weight
lnstitute
task and description of measurements
radiation
with the shortest wavelength (100 to 280 nm).
the
light source. The radiation dose is measured with a
± 1 K
Specifications
AirZ1ng
UV-Compact
5VDC
UV lamps
1 x 7W
1 pc.
Osram HNS S/E 7W 2G7
8000 h
254 nm
Not specified.
Height 240 mm, 0 66 mm
Not specified.
V D E