3. V364 RFID SYSTEM WIRING:
2 DOORS CONTROLLER CONNECTION EXAMPLE
ON
Battery
ON
Console
To PoE Switch
(IEEE 802.3af
up to 15,4W)
DOOR 1 IN
(Stylos cod.5E1310126)
Back side view
circuit board
DOOR 2 IN
(Stylos cod.5E1310126)
Back side view
circuit board
S1
ATLAS DIN PoE
R
MADE IN ITALY
CH0
CH1
PoE
DOOR 1 OUT
(Stylos cod.5E1310126)
Back side view
circuit board
DOOR 2 OUT
(Stylos cod.5E1310126)
Back side view
circuit board
Power IN
12 VDC - 800 mA
24 VDC - 400 mA
CH2
Relay
Relay
1
2
AUX
For the Stylos address configuration refer to the
Stylos Installation Guide, available at: iseo.com.
WIRING SPECIFICATIONS
Cable 3 x 0,75mm - AWG 18
cables section must be verified by qualified staff).
Total LOCKBUS channel cable length (sum of all
branches): MAX 100mt.
S1
Conductor capacitance < 100pF/m.
Conductors electrical resistance max 90 ohm/Km.
Wires colors reported in the wiring diagrams are just an example.
Suggested configuration for 2 doors
controller: max 4 Stylos readers.
Devices consumption:
- ATLAS = 10 W
- Stylos = 3W
DOOR 1
12 VAC
12 VAC
LOCKBUS
(+) V ALIM
( ) GND
2
(the calculation of the
DOOR 2

Publicité