Important Safety Information - MODENO OFG141NG Manuel D'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT SAFETY INFORMATION

!
WARNING
IF YOU SMELL GAS
• Shut off gas supply to the fire table.
• Extinguish any open fame.
• Do not try lighting any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone.
• Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and repair should be done by a qualified service person. The appliance should be
inspected before use and at least annually by a qualified service person. More frequent cleaning may
be required as necessary. It is imperative that the control compartment, burners, and circulating air
passageways of the appliance are kept clean.
• WARNING: Always shut off gas supply at the shut-off valve and disconnect the quick disconnect
socket from the main gas supply when the fire table is not in using.
• WARNING: Installation and service must be performed by a qualified installer, service agency or gas
supplier.
• WARNING: Failure to follow with the safety warnings and precautions in this manual may result in
serious bodily injury or death, a fire or an explosion causing damage to property.
• IMPORTANT NOTICE: Read and understand all warnings and precautions prior to assembly and
use your gas fire table. Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage.
• NOTE: The use and installation of this product must conform to local codes, or in the absence of
local codes with the National Fuel Gas Code, ANSI Z223.1 • NEPA 54; Natural Fuel Gas code ;
Natural Gas and Propane Installation Code, CSA B149.1; or Propane Storage and Handling code
B149.2; This appliance complies with ANSI Z21.97-2017• CSA2.41-2017 Outdoor Decorative Gas
Appliances Standards.
•Minimum Clearance from Unit to Combustible Materials
72"(182.9cm) minus the height of appliance from the top; 48" (121.9cm) from all sides and back.
•Do not locate this fire table under any overhead enclosure.
•The minimum inlet Natural Gas supply pressure: 3.5'' w.c. (0.87kPa).
The maximum inlet Natural Gas supply pressure: 10.5'' w.c. (2.61kPa).
• The manifold pressure of this appliance is 7'' w.c. (1.74kPa).
• Always use this outdoor fire table on a hard, level non-combustible surface such a concrete, rock or
stone. An asphalt or blacktop surface may not be acceptable for this purpose. Surfaces such as dirt
and grass may prevent the unit from having proper ventilation.
• This gas fire table and its individual shut off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 of psi (3.5 kPa).
• The appliance must be isolated from the gas supply piping system by closing its individual
manual shut off valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psi (3.5 kPa).
• Keep these instructions for future reference. If you are assembling this unit for someone else,
give this manual to him or her to read and keep for f utu re reference.
• This gas fire table must be used ONLY outdoors in a well-ventilated space and shall NOT be
used inside a building, garage, or any other enclosed area.
FIRE TABLE IS FOR OUTDOOR USE ONLY
3 / 20

Publicité

Table des Matières
loading