Specifications; Safety Features; Appliance Specifications - Rinnai EnergySaver ES38 Manuel D'installation Et D'utilisation

Masquer les pouces Voir aussi pour EnergySaver ES38:
Table des Matières

Publicité

Safety Features

• Overheat: The appliance will automatically shut
down when the appliance exceeds a predetermined
temperature.
• Flame Failure: The appliance will automatically
shut down if the burner flame is extinguished.
• Power Failure: The appliance will cut off the gas if
it loses electrical power.

Appliance Specifications

Application
General Description
Operation
Gas Connection
Gas Control
Burners
Temperature Control
Ignition System
Flue System
Humidifier Tray
Electrical Connection
Weight
Noise Level
AFUE Rating
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating
conditions and was determined independently of any installed system.
4

Specifications

For manufactured home (USA only) or mobile home or residential installation
convertible for use with natural gas and liquefied petroleum gases (propane /
LPG) when provision is made for the simple conversion from one gas to the
other.
For commercial setting.
For installation at altitudes up to 10,200 feet (3109 m).
Forced combustion, forced convection, flued gas furnace
Push button electronic
1/2 in NPT
Electronic
Stainless steel Bunsen burner
Electronic thermostat
Electronic spark ignition
The flue must be terminated to atmosphere with only flue components listed
with the appliance's certification. Warranty will be voided if non listed
components are installed.
Capacity - 6.3 pints (3000 cc)
AC 120V, 60 Hz, 121 watts
90 lbs (41 kg)
37-47 dB
Natural Gas: 80.6%
Rinnai Corporation ES38 Manual
• Power Surge Fuse: A glass fuse on the PC board
protects against overcurrent. If the fuse blows then
all indicator lamps will be off.
• Spark Detector: The appliance automatically shuts
down if there is an abnormal spark at ignition.
• Fusible Link: In case the overheat feature
prevents the temperature from rising then the fusible
link will break shutting off the appliance.
Propane: 82.0%

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Rhfe-1004fta

Table des Matières